Role of New Hydrophilic Surfaces on Early Success Rate and Implant Stability: 1-Year Post-loading Results of a Multicenter, Split-Mouth, Randomized Controlled Trial

Author:

Tallarico Marco1,Baldini Nicola2,Gatti Fulvio3,Martinolli Matteo4,Xhanari Erta1,Meloni Silvio Mario5,Gabriele Cervino6,Immacolata Lumbau Aurea5

Affiliation:

1. School of Dentistry, University of Sassari, Sassari, Italy

2. Department of Periodontics and Implantology, University of Siena, Siena, Italy

3. Department of Biomedical, Surgical and Dental Sciences, Unit of Oral Surgery, San Carlo and San Paolo Hospital, University of Milan, Milan, Italy

4. Private Practice in Porto Viro, Porto Viro, Italy

5. Medical Surgical and Experimental Science Department, University of Sassari, Sassari, Italy

6. Department of BIOMORF, School of Dentistry, University of Messina, Messina, Italy

Abstract

Abstract Objective To compare early implant failure and implant stability of one-stage Hiossen ET III implants with its new hydrophilic (NH) surface, compared with Hiossen ET III implants with the sandblasted and acid-etched (SA) surface at 1-year follow-up. Materials and Methods This study was designed as a split-mouth, multicenter randomized controlled trial aimed to compare SA surface implants (SA group) and NH surface, (NH group). Outcomes were implant and prosthetic survival rates, complications, the insertion torque at implant placement, and implant stability quotient (ISQ) values. Results Twenty-nine patients (mean age 59.9 ± 11.3 years) were treated and followed up to 1 year after loading. No patient dropped out. Fifty-eight implants (29 SA group and 29 NH group) were placed. No implants or prostheses failed and no complications were experienced during follow-up. The mean insertion torque was 40.5 ± 3.23 (38.17–41.83) Ncm in the SA group and 40.48 ± 3.49 (38.02–41.98) Ncm in the NH group (p = 0.981). There was a statistically significant difference at the second week (T2) with higher values in the NH group (p = 0.041). Similar results were found in the maxilla (p = 0.045), but not in the mandible (p = 0.362). A positive correlation was found between initial insertion torque and ISQ with higher value in the NH group (0.73 vs. 0.66). Conclusions NH implants are a viable alternative to SA surface, as they seem to avoid the ISQ drop during the bone remodeling phase.

Funder

University funding

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3