Preoperative Metal Patch Testing and Titanium Bar Use Criteria in Nuss Procedure: A 56-Patients' Cohort Study

Author:

Pereira-Nunes Joana12ORCID,Vasconcelos-Castro Sofia3ORCID,Fontoura-Matias José12,Preto-Gomes Nuno4,Marinho-Cunha Ana4,Soares-Oliveira Miguel3

Affiliation:

1. Department of Pediatrics, Centro Hospitalar Universitário de São João Ringgold Standard Institution, Porto, Porto, Portugal

2. Department of Gynecology-Obstetrics and Pediatrics, Faculty of Medicine, University of Porto, Porto, Portugal

3. Department of Pediatric Surgery, Centro Hospitalar Universitário de São João Ringgold Standard Institution, Porto, Portugal

4. Department of Dermatology, Centro Hospitalar Universitário de São João Ringgold Standard Institution, Porto, Porto, Portugal

Abstract

Abstract Introduction Nuss procedure is the main reason for metal implants use by pediatric and thoracic surgeons. There is an ongoing debate on how to avoid allergic complications. Herein we describe our 8-year experience with systematic preoperative metal patch testing and our selective titanium bar use in Nuss procedure. Materials and Methods This is a single center retrospective observational cohort study of patients who underwent the Nuss procedure from 2013 to 2020. Preoperative metal patch testing was done in all cases. Criteria for titanium bar utilization were: a positive test for a major component of the stainless-steel bar; or a positive metal patch test and a positive history of atopy, food or metal allergy, or previous allergic reaction to an implant or device. Results In total, 56 patients were included. Most were male (91.1%) with a median age of 15.0 (13.0–22.0) years old. 19.6% had a positive preoperative metal patch test and 54.5% of these had no personal history of atopy. Stainless-steel bars were used in 27.3% of those patients and titanium bars were used in 72.7%. One patient had a documented minor allergy reaction. None of the 56 patients required early bar removal. Conclusion Our study suggests that routine preoperative allergy testing and a judicious use of titanium bar are safe and avoid metal allergic complications.

Publisher

Georg Thieme Verlag KG

Subject

Surgery,Pediatrics, Perinatology and Child Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3