Abstract

Abstract Background When using mobile 3D C-arms, impairments in image quality occur due to artefacts caused by metal implants as well as to the limited field of view. To avoid these restrictions, special computed tomography devices were designed, in order to improve image quality and to meet requirements for intraoperative usage. Objectives To analyse practicability and benefits of a mobile intraoperative CT device (Airo, Brainlab, Munich, Germany) on the basis of several parameters that were obtained during a 40-month period. Materials and Methods All procedures that were performed with usage of intraoperative CT between January 2017 and April 2020 were analysed with respect to anatomical region, count of scans, duration of scans, consequences drawn from the scans and use of navigation. Results 354 CT-scans were performed in 171 patients (mean 2.07 [1 – 6] scans per procedure). 47.81% of the procedures were spinal, 52.19% affected the pelvis. 83% of the procedures were navigated. In 22% of patients, improvement in implant placement or reduction was achieved; in most patients (55%), a guidewire for pedicle screws was corrected. The mean scan duration was 10.33 s (3.54 – 21.72). Conclusions Use of intraoperative CT was reliable and helpful. Integration in OR standards requires more effort than mobile 3D C-arms. Image quality was outstanding for intraoperative conditions and allowed proper assessment of implant placement and reduction in all cases. Due to the high financial outlay of the system and the good image quality of 3D C-arms in the extremities, we assume that this procedure can be applied in intraoperative CT in traumatological cases in spinal and pelvic surgery in high-level trauma centres.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3