Postoperative Monitoring of Free DIEP Flap in Breast Reconstruction with Near-Infrared Spectroscopy: Variables Affecting the Regional Oxygen Saturation

Author:

Salgarello Marzia1,Pagliara Domenico1,Rossi Marco2,Visconti Giuseppe1,Barone-Adesi Liliana1

Affiliation:

1. Department of Plastic and Reconstructive Surgery, Catholic University Sacred Heart – Policlinico Agostino Gemelli, Rome, Italy

2. Department of Anesthesia, Perioperative Medicine and Pain Therapy, Catholic University Sacred Heart – Policlinico Agostino Gemelli, Rome, Italy

Abstract

Background The timing of surgical reexploration in microanastomotic thrombosis is directly related to the salvage rate of free flap. Near-infrared spectroscopy (NIRS) is a noninvasive technique, which allows a continuous bedside monitoring of flap oxygenation. The current literature is lacking in the assessment of variables able to modify the NIRS monitoring. The aim of this study is to identify patient and flap-related variables that can affect regional oxygen saturation (rSO2). Methods We retrospectively analyzed the data obtained from 45 consecutive patients undergoing breast reconstruction with deep inferior epigastric perforator (DIEP) flap. The monitoring device used is the Somanetics INVOS 5100C Cerebral/Somatic Oximeter (Covidien). Baseline measures of demographic–anthropometric variables (age, weight, height, body mass index [BMI]) and flap factors (flap size in grams, skin flap area in square centimeters, perforator number, and perforator size in millimeters) were collected from preoperative and intraoperative assessment. We investigated the linear correlation between mean rSO2 and BMI, flap size, skin flap area, perforator number, and perforator size. Results A positive linear correlation between rSO2 values and skin flap area, perforator number, and perforator size was found. A negative linear correlation between rSO2 values and BMI and flap size was found. All correlations are statistically significant. Despite the overall negative linear correlation between rSO2 values and flap size, we observed a bimodal trend: a positive relation up to 800 g, which is inverted above 800 g. Conclusion The NIRS is a reliable additional tool in free flap monitoring. A careful evaluation should be given to patients and surgery factors that can change the oximetry data.

Publisher

Georg Thieme Verlag KG

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3