Study of a Proposed International Standard for Blood Coagulation Factor IX

Author:

Brozović Milica,Kirkwood T. B. L,Robertson Iris

Abstract

SummaryAn International Collaborative Study was organized to establish a standard for factor IX. Two freeze-dried concentrate preparations, C1 and C2, and one freeze-dried plasma P were compared with each other, with fresh normal plasmas and with local standards in 13 laboratories. One of the concentrate preparations (C1) contained heparin and this gave rise to non-parallel assays in laboratories testing concentrate C1 in dilutions containing more than 0.05 i.u. of heparin per ml.Assays of factor IX showed good precision for both plasma and concentrate in all laboratories; no systematic effect of method, operator or day of assay was detected.The plasma preparation P and the concentrate preparation C2 were compared with 59 individual fresh normal plasma samples, and a mean potency ratio of 0.78 (95% confidence Hmits 0.73-0.84) for plasma and 5.62 (95 % confidence limits 5.13-6.16) for the concentrate C2 obtained. Only 21 estimates of concentrate C1 in terms of fresh plasma were obtained giving a mean potency ratio of 3.85 (95% confidence limits 1.87—7.92).The estimated loss of potency for freeze-dried plasma stored at — 20° C is approximately 0.4% per year. The concentrate C2 is apparently more stable and only very small losses occurred even at higher storage temperatures.All participants agreed that the preparation C2 would be suitable to serve as an International Standard for factor IX; they also agreed that the figure assigned for the unitage should be based on the number of ml of ‘average fresh normal plasma’ estimated to contain the factor IX activity of one ampoule of the preparation. It is proposed to recommend to the World Health Organization that the preparation of factor IX concentrate C2, in ampoules coded 72/32, be considered for establishment as the International Standard for factor IX, and that the international unit for factor IX be assigned on the basis of 5.62 units per ampoule of this preparation.

Publisher

Georg Thieme Verlag KG

Subject

Hematology

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3