Comparison of Hand-Sewn versus Coupled Venous Anastomoses in Traumatic Lower Extremity Reconstruction

Author:

Rifkin William1,Lee Z-Hye1,Anzai Lavinia1,Jacoby Adam1,Ceradini Daniel1,Thanik Vishal1,Saadeh Pierre1,Levine Jamie1,Stranix John1

Affiliation:

1. Hansjörg Wyss Department of Plastic and Reconstructive Surgery, New York University Langone Health, New York, New York

Abstract

Background Microvascular reconstruction of the lower extremity has the highest reported complication and flap failure rates of any anatomical region. Despite widespread adoption of the mechanical anastomotic venous coupler and encouraging results in other anatomical regions, there are limited reports examining its use in the lower extremity. This study compares outcomes between coupled and hand-sewn venous anastomoses in traumatic lower extremity reconstruction. Methods Retrospective review of our institutional flap registry from 1979 to 2016 identified soft tissue free flaps performed for the reconstruction of Gustilo type IIIB/IIIC open tibial fractures. Patient demographics, flap characteristics, use of a venous anastomotic coupler, and perioperative outcomes were examined. Analysis was performed using chi-square and Student's t-tests. Results A total of 361 patients received a microvascular free flap for coverage of a Gustilo type IIIB or IIIC tibial fracture following traumatic injury. After excluding cases that lacked adequate information on coupler use, 358 free flaps were included in the study. There were 72 (20%) free flaps performed using a venous coupler and 286 (80%) performed with hand-sewn venous anastomoses. There were comparable rates of major complications (22.2 vs. 26.1%; p = 0.522), total flap failure (6.5%, vs. 10.2%; p = 0.362), and partial flap failure (9.7 vs. 12.2%; p = 0.579) between venous coupler and hand-sewn anastomoses, respectively. Furthermore, use of the venous coupler was not associated with increased rates of operative take backs (22.8 vs. 23.0%; p = 0.974). However, reconstructions performed using a venous coupler were significantly more likely to have a second venous anastomosis performed (37.5 vs. 21.3%; p = 0.004). Conclusion Complication and flap failure rates were similar between reconstructions performed with a venous coupler and those performed with hand-sewn venous anastomoses. These findings suggest that use of the venous anastomotic coupler is safe and effective in lower extremity reconstruction, with comparable outcomes to conventional sutured anastomoses.

Publisher

Georg Thieme Verlag KG

Subject

Surgery

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3