Affiliation:
1. The Coagulation Laboratory, General Hospital, Malmö, Sweden
2. National Institute for Biological Standards and Control, London NW3 6RB, England
Abstract
SummaryThe recovery and half-life of VIII: C in the plasma of severely haemophilic patients was measured by one-stage and two-stage assays after injection of two Factor VIII concentrates (Hemofil, Hyland and Fraction I-O, Kabi). Plasma volumes were measured with an Evans� Blue technique, and both concentrates and post-infusion samples were measured against the same plasma standard.There was a highly significant difference in recoveries estimated by the two assay methods. The one-stage assays gave the most consistent results, in that the average recovery was 100%, whereas the two-stage assays gave only about 80% of the value expected from in vitro assays. There was no difference in recoveries between the two concentrates.The two-stage assays gave a slightly shorter half-life than the one-stage assays, and the half-life of Hemofil was also shorter than that of Fraction I-O.
Cited by
44 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献