How Do Transcatheter Heart Valves Fit in Mitral Annuloplasty Rings and Which Combination Can be Recommended?

Author:

Ostovar Roya1,Kuehnel Ralf-Uwe1,Erb Michael1,Hartrumpf Martin1,Claus Thomas1,Haase Robert1,Albes Johannes M.1

Affiliation:

1. Department of Cardiovascular Surgery, Heart Center Brandenburg, University Hospital, Brandenburg Medical School, Bernau bei Berlin, Brandenburg, Germany

Abstract

Background Transcatheter heart valve (THV) as valve-in-ring is increasingly used in the mitral position. Semi-rigid rings may serve as a more appropriate scaffold for proper anchoring of a THV as they may change from their oval to a round shape thereby fitting to the implanted THV. Methods One rigid and five semi-rigid rings of four manufacturers, Edwards Physio I and II, Sorin 3D Memo, Medtronic Simulus, and St. Jude Medical (SJM) Saddle and SJM Sequin, with sizes 28 to 36 mm and Edwards Sapien III THV 23, 26, and 29 mm were used. Preevaluation comprised insertion/inflation of the THV into the ring and visual inspection for the paravalvular gap ≥ 4 mm2. Only valves not showing paravalvular gap were then submitted to hemodynamic evaluation with a pulse duplicator. Cusp movement was assessed with a high-speed-camera. Mean transvalvular gradients (TVGs) were measured. Results SJM Saddle ring of all sizes and SJM Sequin ring 34 showed marked gaps combined with all THV sizes, thus not undergoing hemodynamic testing. It was further shown that ring sizes ≥ 36 mm did not allow for a proper fit of even the largest THV into the ring of all the manufacturers and were consequently not hemodynamically evaluated. The 23 mm THV was too small for any ring size. The lowest gradients were achieved with the 26 mm THV in 30 and 32 mm and the 29 mm THV in 32 and 34 mm rings. Conclusion Not all currently available annuloplasty rings are ideal scaffolds for THV placement. It appears that a more proper fit can be achieved with semi-rigid rings than with rigid ones. Note that 23 mm THV appeared to be too small for an adequate anchoring in even the smallest available ring. Thus, 26 mm as well as 29 mm THV fit properly in ring sizes between 28 and 34 mm. Surgeons may consider to choose from those ring brands and sizes which allow for good placement of a THV in view of possible valve degeneration in the later course.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3