Abstract

SummaryA multicenter study of a chromogenic substrate method for photometric determination of prothrombin time was conducted in order to evaluate its clinical application. Seven laboratories pailicipaled in the study using a total of 742 plasma samples from 417 patients on oral anticoagulant therapy, 261 healthy subjects and 64 patients with different diseases especially of the liver as well as 30 patients with hereditary deficiency of coagulation factors II, V, VII, X. The chromogenic PT method was compared to a standardized coagulometric PT assay which uses the same sensitive human placenta thromboplastin calibrated against international reference preparations. A high correlation of the prothrombin ratio values of the chromogenic and the coagulometric assay was obtained in 402 plasma samples (r = 0.940; y = 1.02x − 0.1). The study showed that the chromogenic PT reagent is sensitive to deficiency of the coagulation factors of the extrinsic pathway but not affected by heparin up to 1 IU/ml because of the heparin antagonist added. The precision (coefficient of variation) of the photometric method ranged between 0.6 and 3% (intraassay CV) and between 1.4 and 5.8 (interassay CV). The International Sensitivity Index (ISI) obtained for the used lot was 1.09. The therapeutical range in percentage activity for patients in a stable phase of an anticoagulant therapy was found to be from 15 to 27 percent of normal. The results of the clinical evaluation proved the good comparability of the new chromogenic PT test with coagulometric methods, its high factor sensitivity, good reproducibility and easy performance.

Publisher

Georg Thieme Verlag KG

Subject

Hematology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3