Abstract

Objective The aim of this study was to evaluate and compare the effect of three clinically applicable screw hole diameters on rabbit femoral torsional structural properties. Sample Eighteen pairs of skeletally mature New Zealand White rabbit femora (36 bones). Materials and Methods Femora with a bicortical hole at mid-diaphysis from one of the 3-drill bit sizes, 1.1 mm, 1.5 mm, 2.0 mm, and intact bones were studied. Each bone was bi-axially loaded in a servo-hydraulic load frame with the bone positioned so the neutral axis of torsion was aligned with the centre of the bone diaphysis. Axial compression to 35% body weight was applied to represent compression at stance, and rapid external torsion was applied to failure. Torque and angular deformation data were plotted for each test, with pre-yield and post-yield stiffnesses derived. Yield and failure torques and angles were determined, along with calculated yield, failure and post-yield energies. Results Failure torque was reduced compared with that of intact bone; weakened by 37% in 1.1-mm hole models, 53% in 1.5-mm hole models and 65% in 2.0-mm hole models. The torque angular deformation curves lacked plastic deformation. Conclusions and Clinical Relevance This study demonstrates the unique, brittle biomechanics of rabbit bone. Based on data from other species that strength loss of no more than 50% is acceptable when placing orthopaedic implants, no defect greater than 1.1 mm (15% bone diameter) is recommended in rabbit femora.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3