Author:
Yasukouchi Taro,Fujine Masaru,Kohn Sukehiro,Sakurama Shoki,Morioka Tokiyo,Mikami Akio,Iju Morimasa,Nakagawa Shoichi
Abstract
SummaryThe optimal conditions for the measurement of the fibrinolytic factors of plasma were examined using human and bovine plasminogen-rich fibrinogen or plasminogen-free fibrinogen as the substrates using the one dimensional diffusion method.The results were as follows:1. There was no essential difference found between using human or bovine fibrinogen.2. The levels of proactivator-plasminogen and plasminogen could be measured while using either plasminogen-rich or plasminogen-free fibrinogen. But, in using the latter, the proactivator-plasminogen level could not be measured, if a final concentration of more than 2,000 Christensen units of streptokinase were employed.3. When using plasminogen-rich fibrinogen, anti-plasmin(s) and anti-activator(s) could be measured while using urokinase and plasmin, but not while using streptokinase. However, further study should be given to the measurement of the inhibitors, when using plasminogen-free fibrinogen.