Diagnostic yield of early repeat colonoscopy after suboptimal bowel preparation in a fecal immunochemical test-based screening program

Author:

Baile-Maxía Sandra1,Mangas-Sanjuan Carolina1,Medina-Prado Lucía1,Martínez-Sempere Juan1,Murcia Oscar1,Ruíz-Gómez Francisco1,Casellas Juan A.1,Zapater Pedro2,Jover Rodrigo1

Affiliation:

1. Gastroenterology Department, Hospital General Universitario de Alicante, Instituto de Investigación Biomédica ISABIAL, Alicante, Spain

2. Clinical Pharmacology Department, Hospital General Universitario de Alicante, Instituto de Investigación Biomédica ISABIAL, CIBERehd, Alicante, Spain

Abstract

Abstract Background Current guidelines regarding surveillance after screening colonoscopy assume adequate bowel preparation. However, follow-up intervals after suboptimal cleansing are highly heterogeneous. We aimed to determine the diagnostic yield of early repeat colonoscopy in patients with suboptimal bowel preparation in fecal immunochemical test (FIT)-based screening colonoscopy. Methods An observational study including patients who underwent colonoscopy with suboptimal bowel preparation after positive FIT screening and then repeat colonoscopy within 1 year. Suboptimal preparation was defined as a Boston Bowel Preparation Scale (BBPS) score of 1 in any segment. Patients with a BBPS score of 0 in any segment or incomplete examination were excluded. The adenoma detection rate (ADR), advanced ADR (AADR), and colorectal cancer rate were calculated for the index and repeat colonoscopies. Results Of the 2474 patients with FIT-positive colonoscopy at our center during this period, 314 (12.7 %) had suboptimal preparation. Of the 259 (82.5 %) patients who underwent repeat colonoscopy, suboptimal cleansing persisted in 22 (9 %). On repeat colonoscopy, the ADR was 38.7 % (95 %CI 32.6 % to 44.8 %) and the AADR was 14.9 % (95 %CI 10.5 % to 19.4 %). The per-adenoma miss rate was 27.7 % (95 %CI 24.0 % to 31.6 %), and the per-advanced adenoma miss rate was 17.6 % (95 %CI 13.3 % to 22.7 %). After repeat colonoscopy, the post-polypectomy surveillance recommendation changed from 10 to 3 years in 14.7 % of the patients with previous 10-year surveillance recommendation. Conclusions Patients with suboptimal bowel preparation on FIT-positive colonoscopy present a high rate of advanced adenomas in repeat colonoscopy, with major changes in post-polypectomy surveillance recommendations.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3