Abstract

AbstractSince 2019, a surgery supporting system (SPM, surgical process manager; Johnson & Johnson, New Brunswick, New Jersey, Vereinigte Staaten) has been used in a Level I trauma center for common trauma surgery procedures (distal radius fractures, proximal femur fractures, ankle fractures, proximal humerus fractures, and spine fractures). The hypothesis of this study was that implementing standardized procedures (by using SPM) may reduce radiation exposure, especially for unexperienced surgeons.Workflows were developed for different surgical procedures (distal radius fractures, proximal femur fractures, ankle fractures, proximal humerus fractures, and spine fractures) and added into the SPM. Between October 2019 and June 2022, 90 surgeries using the SPM were included in the study. A control group was included with 107 surgeries using the same surgical technique. The values measured were the radiation exposure during the surgical procedure, the experience of the head surgeon, and whether or not the SPM was used. A statistical analysis was performed by using the chi square and Fischer exact tests, with significance set at a p value < 0.05.SPM was applicated in 51 cases for the distal radius (control group 54 patients), 20 cases for distal fibula fractures (control group 21 patients), 9 cases for the proximal femur (control group 19 patients), 5 cases for vertebral fractures (control group 7 patients), and 5 cases for the proximal humerus (control group 6 patients). No difference concerning the median radiation exposure was observed by plating distal radius fractures with 5.7 Gy/cm² in the SPM group and a median radiation exposure of 6.4 Gy/cm² in the control group (p = 0.96). The distal fibula fractures showed no significant difference in the intraoperative radiation (17.4 Gy/cm² vs. 6.4 Gy/cm², p value 0.53). Radiation exposure was lower when a consultant performed surgery without showing any significance, independent if SPM was used or not.In this study, no significant difference in the intraoperative radiation dose was observed when using a surgery supporting computer system. The experience of the surgeon showed no influence as well, regardless if SPM was used or not. Additional data should be collected questioning these findings.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3