Changes in Anterior Segment Morphology and Intraocular Pressure after Cataract Surgery in Non-glaucomatous Eyes

Author:

Giglio Rosa1,Inferrera Leandro1,De Giacinto Chiara1,DʼAloisio Rossella2,Beccastrini Andrea1,Vinciguerra Alex Lucia1,Perrotta Alberto Armando1,Toro Mario Damiano34,Zweifel Sandrine5,Tognetto Daniele1

Affiliation:

1. Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy

2. Ophthalmology Clinic, Department of Medicine and Science of Ageing, University “G. DʼAnnunzio” of Chieti Pescara, Chieti, Italy

3. Eye Clinic, Department of Public Health, University of Naples Federico II, Napoli, Italy

4. Chair and Department of General and Paediatric Ophthalmology, Medical University of Lublin, Lublin, Poland

5. Department of Ophthalmology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

Abstract

Abstract Background It is known that cataract extraction is associated with a significant reduction in intraocular pressure, especially in narrow angled eyes; however, the modifications of anterior segment parameters associated with this phenomenon have still not been completely defined. The purpose of this study was to evaluate changes in anterior segment anatomy and intraocular pressure after cataract surgery in non-glaucomatous eyes. Methods and Material This retrospective case series study included 64 eyes of 64 consecutive patients who underwent phacoemulsification with intraocular lens implantation. Anterior segment parameters and intraocular pressure were assessed and compared before and 6 months after surgery. Anterior segment imaging was performed using Casia SS-1000 anterior segment optical coherence tomography (Tomey, Nagoya, Japan). Anterior segment measurements included anterior chamber depth, anterior chamber width, anterior chamber volume, angle opening distance at 500 µm anterior to the scleral spur, angle recess area 750 µm from the scleral spur, lens vault, trabecular iris space area at 500 µm from the scleral spur, and trabecular iris angle at 500 µm from the scleral spur. Intraocular pressure was measured using the Goldmann applanation tonometer (Model AT 900 C/M, Haag-Streit, Bern, Switzerland). Anterior segment parameters and the relationship of changes in intraocular pressure were also evaluated. Results All anterior segment parameters increased significantly after surgery (p < 0.05). Both angle opening distance at 500 µm anterior to the scleral spur and anterior chamber depth changes were positively correlated with the preoperative lens vault. The mean intraocular pressure significantly decreased from 14.91 mmHg (± 2.8 SD) to 12.91 mmHg (± 3.13 SD) (p < 0.001). Changes in intraocular pressure correlated negatively with values for the width of the preoperative anterior chamber (r = − 0.533; p = 0.001). Conclusion Cataract surgery led to significant widening of the anterior chamber angle and lowering of intraocular pressure. Further investigations are needed to better understand whether anterior chamber width may be a new independent predictive factor for reduction in postoperative intraocular pressure.

Publisher

Georg Thieme Verlag KG

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3