Accuracy and Reproducibility of a Software Prototype for Semi-Automated Computer-Aided Volumetry of the solid and subsolid Components of part-solid Pulmonary Nodules

Author:

Werner Sebastian1ORCID,Gast Regina1,Grimmer Rainer2,Wimmer Andreas3,Horger Marius1

Affiliation:

1. Radiology, University Hospitals Tübingen, Tübingen, Germany

2. Medical Imaging, Siemens Healthineers AG, Erlangen, Germany

3. Siemens Healthcare GmbH, Forchheim, Germany

Abstract

Purpose To test the accuracy and reproducibility of a software prototype for semi-automated computer-aided volumetry (CAV) of part-solid pulmonary nodules (PSN) with separate segmentation of the solid part. Materials and Methods 66 PSNs were retrospectively identified in 34 thin-slice unenhanced chest CTs of 19 patients. CAV was performed by two medical students. Manual volumetry (MV) was carried out by two radiology residents. The reference standard was determined by an experienced radiologist in consensus with one of the residents. Visual assessment of CAV accuracy was performed. Measurement variability between CAV/MV and the reference standard as a measure of accuracy, CAV inter- and intra-rater variability as well as CAV intrascan variability between two recontruction kernels was determined via the Bland-Altman method and intraclass correlation coefficients (ICC). Results Subjectively assessed accuracy of CAV/MV was 77 %/79 %–80 % for the solid part and 67 %/73 %–76 % for the entire nodule. Measurement variability between CAV and the reference standard ranged from –151–117 % for the solid part and –106–54 % for the entire nodule. Interrater variability was –16–16 % for the solid part (ICC 0.998) and –102–65 % for the entire nodule (ICC 0.880). Intra-rater variability was –70–49 % for the solid part (ICC 0.992) and –111–31 % for the entire nodule (ICC 0.929). Intrascan variability between the smooth and the sharp reconstruction kernel was –45–39 % for the solid part and –21–46 % for the entire nodule. Conclusion Although the software prototype delivered satisfactory results when segmentation is evaluated subjectively, quantitative statistical analysis revealed room for improvement especially regarding the segmentation accuracy of the solid part and the reproducibility of measurements of the nodule’s subsolid margins. Key points: 

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Reference29 articles.

1. Focal ground-glass opacity detected by low-dose helical CT;M Nakata;Chest,2002

2. Incidental, subsolid pulmonary nodules at CT: etiology and management;J L Seidelman;Cancer Imaging,2013

3. Transient part-solid nodules detected at screening thin-section CT for lung cancer: comparison with persistent part-solid nodules;S M Lee;Radiology,2010

4. Pulmonary subsolid nodules: what radiologists need to know about the imaging features and management strategy;H Kim;Diagn Interv Radiol,2014

5. Guidelines for Management of Incidental Pulmonary Nodules Detected on CT Images: From the Fleischner Society 2017;H MacMahon;Radiology,2017

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Artificial Intelligence in Oncological Hybrid Imaging;Nuklearmedizin - NuclearMedicine;2023-10

2. Factors influencing the outcome of volumetry tools for pulmonary nodule analysis: a systematic review and attempted meta-analysis;Insights into Imaging;2023-09-23

3. Artificial Intelligence in Oncological Hybrid Imaging;RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren;2022-09-28

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3