Key performance measures for colonoscopy in the Polish Colonoscopy Screening Program

Author:

Bugajski Marek12,Rupinski Maciej12,Wieszczy Paulina23,Pisera Małgorzata3,Regula Jaroslaw12,Kaminski Michal F.14

Affiliation:

1. Department of Gastroenterological Oncology, The Oncology Center, Maria Curie Institute, Warsaw, Poland

2. Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Center for Postgraduate Education, Warsaw, Poland

3. Department of Cancer Prevention, The Oncology Center, Maria Curie Institute, Warsaw, Poland

4. Department of Health Management and Health Economics, University of Oslo, Oslo, Norway

Abstract

Abstract Background The European Society of Gastrointestinal Endoscopy (ESGE) has published guidelines on key performance measures for colonoscopy. We analyzed whether those standards were met in the Polish Colonoscopy Screening Program (PCSP) and whether the monitoring was feasible. Methods We analyzed database records for 43 277 PCSP participants (25 PCSP centers) for the years 2014 – 2015. We used the guideline definitions to calculate values for all key performance measures and compared these with the proposed standards at individual, center, and program level. All data were acquired from the PCSP database, apart from complication data which was assessed from external registries. Results At the program level, four of five minimum standards and one of two target standards (no set minimum standard) were met. Adequate bowel preparation rate was 91.3 % for the whole program (range among individual centers 79.2 % – 99.2 %). Cecal intubation rate was 97.4 % (93.4 % – 99.4 %). Adenoma detection rate was 29.8 % (19.1 % – 39.1 %). An appropriate polypectomy technique was applied in 62.7 % of cases (0.4 % – 97.8 %). Regarding complications, 7-day hospitalization rate after screening colonoscopy was 0.3 % (n = 127), and 30-day all-cause mortality was 0.02 % (n = 9). Patient feedback was assessed in 66.2 % of colonoscopies (7.6 % – 81.8 %). Appropriate post-polypectomy surveillance was proposed in 95.4 % of cases (range 84.9 % – -99.7 %). It was easy to monitor 6 of 7 key performance measures within the PCSP database, but monitoring complications required the additional effort of data extraction from external registries. Conclusions The PCSP meets most proposed minimum standards at program level. Some centers need additional interventions to meet the complete set of quality standards. Use of ESGE performance measures for monitoring colonoscopy is generally feasible in the setting of the colonoscopy screening program.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3