Volumetric laser endomicroscopy and optical coherence tomography in Barrett’s esophagus: a systematic review and meta-analysis

Author:

Rodriguez Maria Auxiliadora Chóez1ORCID,de Moura Diogo Turiani Hourneaux2ORCID,Ribeiro Igor Braga1ORCID,Bernardo Wanderley Marques1ORCID,Morita Flavio Hiroshi Ananias1ORCID,Marques Sergio Barbosa1ORCID,Sakai Paulo1ORCID,de Moura Eduardo Guimarães Hourneaux1ORCID

Affiliation:

1. Department of Endoscopy, Hospital das Clínicas, University of São Paulo School of Medicine, São Paulo, Brazil

2. Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States

Abstract

Abstract Background and study aims Endoscopic imaging of Barrett’s esophagus (BE) with advanced technologies, such as optical coherence tomography (OCT) and volumetric laser endomicroscopy (VLE), allows targeted biopsies and may reduce the number of random biopsies to detect esophageal neoplasia in the early stages during endoscopic BE surveillance. The aim of this study was to evaluate the accuracy of OCT and VLE in diagnosis of intestinal metaplasia, dysplasia, and high-grade dysplasia (HGD), and intramucosal carcinoma (IMC) in BE. Patients and methods In this systematic review and meta-analysis, the primary outcome measure was diagnostic accuracy of OCT and VLE, in comparison with the gold standard. In the meta-analysis, we calculated sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for both methods. We performed analyses by patient and by lesion. Results We evaluated 14 studies involving a collective total of 721 patients and 1565 lesions. In the analysis by lesion, VLE showed a pooled sensitivity, specificity, LR+, LR−, DOR, and SROC AUC of 85 %, 73 %, 3.2, 0.21, 15.0, and 0.87, respectively, for detection of HGD/IMC. In the analysis by lesion for detection of HGD/EAC, OCT showed a pooled sensitivity, specificity, LR+, LR−, DOR, and summary receiver operating characteristic area under the curve of 89 %, 91 %, 9.6, 0.12, 81.0, and 0.95, respectively. The accuracy of OCT in identifying intestinal metaplasia showed a pooled sensitivity, specificity, LR+, LR−, and DOR of 92 %, 81 %, 5.06, 0.091, and 55.58, respectively. Conclusion OCT- and VLE-guided targeted biopsies could improve detection of dysplasia and neoplasia. Further studies could determine whether the use of such biopsies might replace the current protocol.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ex vivo optical coherence tomography combined with near infrared targeted fluorescence: towards in-vivo esophageal cancer detection;Biomedical Optics Express;2024-09-05

2. Research progress on the application of optical coherence tomography in the field of oncology;Frontiers in Oncology;2022-07-25

3. Advanced Imaging Techniques and In Vivo Histology: Current Status and Future Perspectives (Upper G.I.);Gastrointestinal and Pancreatico-Biliary Diseases: Advanced Diagnostic and Therapeutic Endoscopy;2021-11-09

4. Role of optical coherence tomography in Barrett’s esophagus;Artificial Intelligence in Gastrointestinal Endoscopy;2021-08-28

5. Artificial intelligence: Thinking outside the box;Best Practice & Research Clinical Gastroenterology;2021-06