The Transseptal Arthroscopic Knee Portal Is in Close Proximity to the Popliteal Artery: A Cadaveric Study

Author:

Cancienne Jourdan1,Werner Brian1,Burrus M.1,Kandil Abdurrahman1,Conte Evan1,Gwathmey Frank1,Miller Mark1

Affiliation:

1. Department of Orthopaedic Surgery, University of Virginia Health System, Charlottesville, Virginia

Abstract

AbstractThe purpose of this study was to use fluoroscopy to measure the distance between the transseptal portal and the popliteal artery under arthroscopic conditions with an intact posterior knee capsule, and to determine the difference between 90 degrees of knee flexion and full extension. The popliteal artery of eight fresh-frozen cadaveric knees was dissected and cannulated proximal to the knee joint. The posterolateral, posteromedial, and transseptal portals were then established at 90 degrees of flexion. A 4-mm switching stick was placed through the transseptal portal, and barium contrast was injected into the popliteal artery. A lateral fluoroscopic image was taken with the knee in 90 degrees of flexion and full extension, and the distance between the popliteal artery and the switching stick was measured and compared using a paired t-test. In knee flexion, the average distance between the transseptal portal and the anterior aspect of the popliteal artery for the eight cadaveric specimens was 12.0 mm ± 3.3 mm; in extension, this decreased to 9.0 mm ± 2.7 mm. The distance between the transseptal portal and popliteal artery was significantly higher at 90 degrees of knee flexion as compared with extension (p = 0.0005). The transseptal posterior knee arthroscopic portal must be carefully created due to the close proximity to the popliteal artery, and may be closer to the artery than previously reported in specimens with an intact posterior knee capsule. Creating the portal with the knee in flexion significantly displaces the popliteal artery away from the portal reducing the risk of arterial injury.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3