Hepatitis C Virus Transmission through Quarantine Fresh-frozen Plasma

Author:

Legler T. J.,Nübling C. M.,Riggert J.,Unger G.,Wolf C.,Heermann K.-H.,Köhler M.,Humpe A.

Abstract

SummaryIn 1994, quarantine fresh-frozen plasma (Q-FFP) was introduced in Germany in order to reduce the risk of HIV and HCV transmission. In 1998, an acute HCV infection of a patient was reported to us. The lookback revealed that this patient had received two Q-FFP from a donor who had seroconverted for HCV in the meantime. Recipients of further plasma donations from this donor were identified. Back-up specimens of these donations were investigated in several laboratories. A total of 25 additional HCV-PCR positive plasma units had been transfused to 12 further patients. HCV infections were diagnosed in seven of these recipients, three patients had already been deceased. One of the remaining two recipients was already HCV positive prior to transfusion, in the other patient, no HCV infection was detectable. This patient had received three units of an “early” plasma donation , which was tested negative by PCR in one laboratory, but positive in the other. The subsequent, clinically infectious donation had the same discrepant PCR results. Thus, eight cases of HCV transmission were revealed and classified as “certain” with regard to causality, also due to an identical HCV genotype, i.e. 3e. Some of these infections would have been prevented by application of a different anti-HCV assay. The assay used in the respective plasmapheresis station was in-sensitive in this individual case for more than 400 days after the first PCR positive donation. This caused the release of the above mentioned infectious units. Upon re-testing the backups, three of four other anti-HCV assays revealed a positive result already 104 days after the first PCR-positive donation. The donor had increased ALAT levels (> 23 IU/L) at nine of 28 donations, two of these were higher than 2.5 times the upper normal limit, and two were higher than 68 IU/L, which is the cut-off value for male blood donors in Germany. The results of these (look-back) studies arouse several queries, i.e. differences in the diagnostic sensitivity between current anti-HCV and PCR tests, the accuracy of risk-estimates (especially when based on hemovigilance studies for Q-FFP), the value of ALAT testing, and currently practised release algorithms for Q-FFP.

Publisher

Georg Thieme Verlag KG

Subject

Hematology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3