Treatment of Mandibular Angle Fractures with Single Three-Dimensional Locking Miniplates without Maxillomandibular Fixation: How Much Fixation is Required?

Author:

Rastogi Sanjay1,Paul Sam2,Kukreja Sumedha3,Aggarwal Karun4,Choudhury Rupshikha5,Bhugra Amit6,Niranjana Prasad Indra B.6,Jawaid Moazzam7

Affiliation:

1. Department of Oral and Maxillofacial Surgery and Oral Implantology, TMDCRC, Moradabad, Uttar Pradesh, India

2. Department Orthodontics and Dentofacial Orthopaedics, Educare Institute of Dental Sciences, Chattiparamba, Malappuram, Kerala, India

3. Department of Oral and Maxillofacial Surgery, Lady Hardinge Medical College, New Delhi, India

4. Department of Oral and Maxillofacial Surgery, Jodhpur Dental College and Research Center, Jodhpur, Rajasthan, India

5. Department of Oral and Maxillofacial Surgery, Regional Dental College, Guwahati, Assam, India

6. Department of Oral and Maxillofacial Surgery, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India

7. Department of Oral Medicine and Radiology, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India

Abstract

The aim of this simple nonrandomized and observational study was to evaluate the efficacy of single three-dimensional (3D) plate for the treatment of mandibular angle fractures without maxillomandibular fixation. A total of 30 patients with noncomminuted fractures of mandibular angle requiring open reduction and internal fixation were included in the study. All the patients were treated by open reduction and internal fixation using single 3D titanium locking miniplate placed with the help of transbuccal trocar or Synthes 90-degree hand piece and screw driver. 3D locking titanium miniplates used in our study was four-holed, box-shaped plate, and screws with 2 mm diameter and 8 mm length. The following clinical parameters were assessed for each patient at each follow-up visit: pain (visual analog scale: 0–5), swelling (visual analog scale: 0–5), mouth opening, infection, paresthesia, hardware failure (plate fracture), occlusal discrepancies, and mobility between fracture fragments. A significant decrease in pain level was seen during the follow-up visits. No statistically significant changes were seen in swelling, but mouth opening increased in the subsequent visits. Also better results were seen in terms of fracture stability and occlusion in the postoperative period. Two cases of infection and two cases of hardware failure were noted in sixth postoperative week. 3D plating system is an easy to use alternative to conventional miniplates to treat mandibular angle fractures that uses lesser foreign material, thus reducing the operative time and overall cost of the treatment. Better fracture stability and occlusion was also achieved using the 3D plating system.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Oral Surgery,Surgery

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3