Contrast-enhanced endoscopic ultrasound for the differential diagnosis between benign and malignant lymph nodes: a meta-analysis

Author:

Lisotti Andrea1,Ricci Claudio2,Serrani Marta1,Calvanese Claudio1,Sferrazza Sandro1,Brighi Nicole3,Casadei Riccardo2,Fusaroli Pietro12

Affiliation:

1. Gastroenterology Unit, Department of Medical and Surgical Sciences, University of Bologna, Hospital of Imola, Imola, Bologna, Italy

2. Department Medical and Surgical Sciences (DIMEC), University of Bologna, S.Orsola-Malpighi Hospital, Bologna, Italy

3. Department of Experimental, Diagnostic and Specialty Medicine (DIMES), University of Bologna, Oncology Unit, S. Orsola-Malpighi Hospital, Bologna, Italy

Abstract

Abstract Background The differential diagnosis between benign and malignant lymph nodes (LNs) is crucial for patient management and clinical outcome. The use of contrast-enhanced endoscopic ultrasound (EUS) has been evaluated in several studies with diverse results. The aim of this meta-analysis was to evaluate the pooled diagnostic accuracy of contrast-enhanced EUS (CE-EUS) and contrast-enhanced harmonic EUS (CH-EUS) in this setting. Methods A systematic electronic search was performed, including all original papers dealing with assessment of the nature of the LNs using CE-EUS or CH-EUS. A meta-analysis was performed to obtain pooled sensitivity, specificity, positive and negative likelihood ratio, and diagnostic odds ratio. The Summary Receiver Operating Characteristic (ROC) Curve method was used to calculate the area under the curve. Statistical analysis was carried out using Meta-Disc V.1.4, Stata V.12.0 and Review Manager V.5.2. Results Among 210 pertinent studies, four (336 patients) were included in the analysis. The pooled sensitivity was 82.1 % (75.1 – 87.7 %) and pooled specificity was 90.7 % (85.9 – 94.3 %) with significant heterogeneity found in sensitivity; the positive-likelihood ratio (LR) was 7.77 (5.09 – 11.85) and the negative-LR was 0.15 (0.05 – 0.46); the pooled diagnostic odds ratio (DOR) was 54 (15 – 190). Subgroup analysis including studies performed using CH-EUS (two studies, 177 LNs) showed a pooled sensitivity of 87.7 % (77.0 – 93.9 %) and a pooled specificity of 91.8 % (84.5 % – 96.4 %) with no significant heterogeneity; the pooled positive-LR was 9.51 (4.95 – 18.28) and the pooled negative-LR was 0.14 (0.06 – 0.35); pooled DOR was 68.42 (15.5 – 301.4). Conclusions From these data, CE-EUS is not recommended due to inadequate sensitivity. On the other hand, CH-EUS studies showed optimal accuracy (pooled sensitivity 87.7 % and specificity 91.8 %), comparable to elastography and even EUS-guided fine needle aspiration (EUS-FNA), suggesting a role in the diagnostic algorithm.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3