Inter-Reader Variability Using PI-RADS v2 Versus PI-RADS v2.1: Most New Disagreement Stems from Scores 1 and 2

Author:

Beetz Nick Lasse1ORCID,Haas Matthias1,Baur Alexander1,Konietschke Frank2,Roy Akash3,Hamm Charlie Alexander1,Rudolph Madhuri Monique1,Shnayien Seyd1ORCID,Hamm Bernd1,Cash Hannes4,Asbach Patrick1,Penzkofer Tobias1

Affiliation:

1. Department of Radiology, Charite University Hospital Berlin, Germany

2. Department of Biometry and Clinical Epidemiology, Charite University Hospital Berlin, Germany

3. Biostatistics and Bioinformatics, Duke University School of Medicine, DURHAM, United States

4. Department of Urology, Charite University Hospital Berlin, Germany

Abstract

Purpose To analyze possible differences in the inter-reader variability between PI-RADS version 2 (v2) and version 2.1 (v2.1) for the classification of prostate lesions using multiparametric MRI (mpMRI) of the prostate. Methods In this retrospective and randomized study, 239 annotated and histopathologically correlated prostate lesions (104 positive and 135 negative for prostate cancer) were rated twice by three experienced uroradiologists using PI-RADS v2 and v2.1 with an interval of at least two months between readings. Results were tabulated across readers and reading timepoints and inter-reader variability was determined using Fleiss’ kappa (κ). Thereafter, an additional analysis of the data was performed in which PI-RADS scores 1 and 2 were combined, as they have the same clinical consequences. Results PI-PI-RADS v2.1 showed better inter-reader agreement in the peripheral zone (PZ), but poorer inter-reader agreement in the transition zone (TZ) (PZ: κ = 0.63 vs. κ = 0.58; TZ: κ = 0.47 vs. κ = 0.57). When PI-RADS scores 1 and 2 were combined, the use of PI-RADS v2.1 resulted in almost perfect inter-reader agreement in the PZ and substantial agreement in the TZ (PZ: κ = 0.81; TZ: κ = 0.80). Conclusion PI-RADS v2.1 improves inter-reader agreement in the PZ. New differences in inter-reader agreement were mainly the result of the assignment of PI-RADS v2.1 scores 1 and 2 to lesions in the TZ. Combining scores 1 and 2 improved inter-reader agreement both in the TZ and in the PZ, indicating that refined definitions may be warranted for these PI-RADS scores. Key Points:  Citation Format

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3