Results of a Highly Porous Metal-Backed Cementless Patella Implant: A Minimum 5-Year Follow-Up

Author:

Baker James F.1,Smith Nolan S.2,Likine Elive F.3,Smith Langan S.1,Yakkanti Madhusudhan R.4,Malkani Arthur L.5

Affiliation:

1. ULP Orthopedics, UofL Health, Louisville, Kentucky

2. University of Louisville School of Medicine, Louisville, Kentucky

3. Department of Orthopedic Surgery, University of Louisville, Louisville, Kentucky

4. Louisville Orthopaedic Clinic, Louisville, Kentucky

5. Adult Reconstruction Program, Department of Orthopedic Surgery, University of Louisville, Louisville, Kentucky

Abstract

AbstractInitial design cementless metal-backed patellar implants failed due to multiple reasons including implant design, use of first-generation polyethylene, and surgical technique. This study evaluates clinical outcomes and survivorship of total knee arthroplasty (TKA) using a current generation highly porous metal-backed patellar component. One-hundred twenty-five consecutive primary cementless TKAs with a compression molded highly porous metal-backed patella were reviewed. One-hundred three TKAs (82.4%) with 5-year clinical and radiographic follow-up were available for review. These were matched with 103 consecutive TKAs using a cemented patella of the same implant design. The cementless cohort had a mean age of 65.5 years, body mass index (BMI) of 33.0, and follow-up of 64.4 months. Indications for cementless TKA were based on multiple factors including age, BMI, and bone quality. There were no revisions for loosening or mechanical failure of the cementless patella compared with two cemented patellae revised for aseptic loosening. Eight patients required revisions in the cementless cohort: three for prosthetic joint infection (PJI), two for instability, one periprosthetic femur fracture, one for patella instability, and one for extensor mechanism rupture. Five patients required revisions in the cemented cohort: two for aseptic patellar loosening, one for aseptic femoral loosening, one for PJI, and one for instability. All-cause survivorship at 5 years was 92.2 and 95.1% for the cementless metal-backed implant and cemented implant cohorts, respectively. Use of a compression molded highly porous metal-backed patella component demonstrated excellent clinical and radiographic results at 5-year follow-up. Longer follow-up is required to evaluate the ability of highly porous cementless patella implants to provide durable long-term fixation.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3