Argon plasma coagulation for Barrett’s esophagus with low-grade dysplasia: a randomized trial with long-term follow-up on the impact of power setting and proton pump inhibitor dose

Author:

Wronska Ewa12,Polkowski Marcin12,Orlowska Janina2,Mroz Andrzej34,Wieszczy Paulina15,Regula Jaroslaw12

Affiliation:

1. Department of Gastroenterology, Hepatology and Oncology, Center of Postgraduate Medical Education, Warsaw, Poland

2. Department of Gastroenterological Oncology, Maria Sklodowska-Curie Institute – Oncology Center, Warsaw, Poland

3. Department of Pathomorphology, Center of Postgraduate Medical Education, Warsaw, Poland

4. Department of Pathology and Laboratory Medicine, Maria Sklodowska-Curie Institute – Oncology Center, Warsaw, Poland

5. Department of Cancer Prevention, Maria Sklodowska-Curie Institute – Oncology Center, Warsaw, Poland

Abstract

Background This study evaluated the impact of power setting and proton pump inhibitor (PPI) dose on efficacy and safety of argon plasma coagulation (APC) of Barrett’s esophagus (BE) with low-grade dysplasia (LGD). Methods 71 patients were randomized to APC with power set at 90 W or 60 W followed by 120 mg or 40 mg omeprazole. The primary outcome was the rate of complete (endoscopic and histologic) ablation of BE at 6 weeks. Secondary outcomes included safety and long-term efficacy. Results Complete ablation rate in the 90 W/120 mg, 90 W/40 mg, and 60 W/120 mg groups was 78 % (18/23; 95 % confidence interval [CI] 61–95), 60 % (15/25; 95 %CI 41–79), 74 % (17/23; 95 %CI 56–92), respectively, at 6 weeks and 70 % (16/23; 95 %CI 51–88), 52 % (13/25; 95 %CI 32–72), and 65 % (15/23; 95 %CI 46–85) at 2 years post-treatment (differences not significant). Additional APC was required in 28 patients (23 residual and 5 recurrent BE). At median follow-up of 108 months, 66/71 patients (93 %; 95 %CI 87–99) maintained complete ablation. No high-grade dysplasia or adenocarcinoma developed. Overall, adverse events (97 % mild) did not differ significantly between groups. Chest pain/discomfort was more frequent in patients receiving 90 W vs. 60 W power (P < 0.001). One patient had esophageal perforation and two developed stenosis. Conclusions APC power setting and PPI dose did not impact efficacy and safety of BE ablation. Complete ablation of BE with LGD was durable in > 90 % of patients, without any evidence of neoplasia progression in the long term.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3