Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time

Author:

Kiesslich Ralf1,Teubner Daniel1,Hoffman Arthur2,Rey Johannes W.3

Affiliation:

1. Helios Dr. Horst Schmidt Kliniken (HSK), Klinik für Innere Medizin II, Wiesbaden, Germany

2. Klinikum Aschaffenburg-Alzenau, Klinik für Innere Medizin III, Wiesbaden, Germany

3. Klinikum Osnabrück, Medizinische Klinik III, Wiesbaden, Germany

Abstract

Abstract Background and study aims The newly introduced G-EYE colonoscope (G-EYE) employs a balloon, installed at the bending section of a standard colonoscope (SC), for increasing adenoma detection and stabilizing the colonoscope tip during intervention. This retrospective work explores the effect of introducing G-EYE into an SC endoscopy room, in terms of adenoma detection and polyp removal time. Patients and methods This was a single-center, retrospective study. Historical data from patients who underwent colonoscopy prior to, and following, introduction of G-EYE into a particular endoscopy room were collected and analyzed to determine adenoma detection rate (ADR), adenoma per patient (APP), and polyp removal time (PRT), in each of the SC and G-EYE groups. Results Records of 1362 patients who underwent SC and 1433 subsequent patients who underwent G-EYE colonoscopy in the same endoscopy unit by the same endoscopists were analyzed. Following G-EYE introduction, overall ADR increased by 37.5 % (P < 0.0001) from 39.2 % to 53.9 %, the serrated adenoma rate increased by 47.3 % from 27.9 % to 41.1 % (P < 0.0001), and the APP increased by 50.6 % from 0.79 to 1.19 (P < 0.0001). The number of advanced adenomas increased by 32.7 %, from 19.6 % to 26.0 % of all adenomas (P < 0.0001). With G-EYE, average PRT was reduced overall by 29.5 % (P < 0.0001), and particularly for endoscopic mucosal resection (EMR) by 37.5 % for polyps measuring ≥ 5 mm to ≤ 20 mm (P < 0.0001) and by 29.4 % for large polyps > 20 mm (P < 0.0001). Conclusions Introduction of G-EYE to an SC endoscopy room yielded considerable increase in ADR and notable reduction in PRT, particularly with the EMR technique. G-EYE balloon colonoscopy might increase the effectiveness of colorectal cancer screening and surveillance colonoscopy, and can shorten the time of endoscopic intervention.

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3