22G Acquire vs. 20G Procore needle for endoscopic ultrasound-guided biopsy of pancreatic masses: a randomized study comparing histologic sample quantity and diagnostic accuracy

Author:

Karsenti David1,Palazzo Laurent2,Perrot Bastien3,Zago Jacqueline4,Lemaistre Anne-Isabelle5,Cros Jérôme6,Napoléon Bertrand7

Affiliation:

1. Digestive Endoscopy Unit, Pôle Digestif Paris Bercy, Clinique de Paris-Bercy, Charenton-le-Pont, France

2. Digestive Endoscopy Unit, Clinique du Trocadéro, Paris, France

3. UMR1246_SPHERE Methods for Patient-Centered Outcomes and Health Research, Nantes University, France

4. Pathology Department, 29 rue du Colisée, Paris, France

5. Department of Pathology, Eurofins Biomnis, Lyon, France

6. Beaujon Hospital, Pathology Department, Université de Paris, INSERM U1149, Clichy, France

7. Digestive Endoscopy Unit, Hôpital Privé Jean Mermoz, Ramsay Générale de Santé, Lyon, France

Abstract

AbstractBackground Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) has been suggested for obtaining high quality tissue samples from pancreatic tumors. We performed a multicenter randomized crossover trial comparing EUS-FNB with a 20G Procore needle vs. a 22G Acquire needle. The aims were to compare the quantity of targeted tissue (pancreas) and diagnostic accuracy for the two needles.Methods 60 patients admitted for EUS-FNB in three endoscopy units were included. One pass was performed consecutively with each needle, in a randomized order. Histologic material was studied in a blinded manner with respect to the needle. The primary end point was mean cumulative length of tissue core biopsies per needle pass.Results Final diagnosis was adenocarcinoma (n = 46; 77 %), neuroendocrine neoplasm (n = 11; 18 %), autoimmune pancreatitis (n = 2), and mass-forming chronic pancreatitis (n = 1). The mean cumulative length of tissue core biopsies per needle pass was significantly higher with the 22G Acquire needle at 11.4 mm (95 % confidence interval [CI] 9.0 – 13.8] vs. 5.4 mm (95 %CI 3.8 – 7.0) for the 20G Procore needle (P < 0.001), as was the mean surface area (3.5 mm2 [95 %CI 2.7 – 4.3] vs. 1.8 mm2 [95 %CI 1.2 – 2.3]; P < 0.001). Diagnostic adequacy and accuracy were 100 % and 87 % with the 22G Acquire needle, and 82 % and 67 % with the 20G Procore needle (P = 0.001 and P = 0.02, respectively).Conclusions EUS-guided biopsy of pancreatic masses with the 22G Acquire needle provided more tissue for histologic evaluation and better diagnostic accuracy than the 20G Procore needle.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3