Efficacy of a novel self-assembling peptide hemostatic gel as rescue therapy for refractory acute gastrointestinal bleeding

Author:

de Nucci Germana1,Reati Raffaella1,Arena Ilaria2,Bezzio Cristina2,Devani Massimo2,Corte Cristina della2,Morganti Daniela1,Mandelli Enzo Domenico1,Omazzi Barbara2,Redaelli Davide1,Saibeni Simone2,Dinelli Marco3,Manes Gianpiero12

Affiliation:

1. Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Garbagnate Milanese, Milan, Italy

2. Gastroenterology and Endoscopy Unit, Aziende Socio Sanitaria Territoriale Rhodense – Rho Hospital, Milan, Italy

3. Endoscopy Unit, San Gerardo Hospital, Monza, Italy

Abstract

Abstract Background Acute gastrointestinal bleeding (AGIB) results in significant morbidity and mortality. Topical hemostatic products have been developed for endoscopic use to help in the management of difficult bleeding. Our aim was to demonstrate the ease of use, safety, and efficacy of PuraStat, a novel hemostat, to control AGIB. Methods We describe 77 patients (41 men) who were treated for acute upper and lower AGIB in a 2-year period. In 50 patients, bleeding occurred as a complication of a previous endoscopic procedure, predominantly endoscopic mucosal resection (EMR) and endoscopic retrograde cholangiopancreatography (ERCP); however, in the other 27 patients, it derived from peptic ulcers, angiodysplasia, cancers, and surgical anastomoses. Bleeding was spurting in 13 of the 77 patients and oozing in 64. PuraStat was used after the failure of at least two conventional hemostatic methods. Results A mean of 2.6 conventional hemostatic methods had been attempted prior to the application of PuraStat. PuraStat achieved successful hemostasis in 90.9 % of patients. In 41 patients, once hemostasis was obtained with PuraStat, endoscopists further stabilized hemostasis by using at least one additional method. Recurrence of bleeding was observed in eight patients (10.4 %). In 16 patients with intraprocedural bleeding, it was possible to complete the procedures (14 EMR, 2 ERCP) after PuraStat hemostasis. No adverse events related to PuraStat were recorded. Conclusions PuraStat is feasible, safe, and effective in controlling different types of gastrointestinal hemorrhage after failure of conventional hemostatic methods. Its application also does not hinder continuing endotherapy.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

Cited by 50 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3