Factors Limiting Magnetic Resonance Imaging Diagnosis of Placenta Accreta Spectrum

Author:

Cheng CeCe1ORCID,Ramsey Patrick S.1,Byrne John J.1,Katabathina Venkata S.2,Ireland Kayla E.3,Munoz Jessian L.4ORCID

Affiliation:

1. Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, University of Texas Health Science Center at San Antonio, Texas

2. Department of Radiology, University of Texas Health Science Center at San Antonio, Texas

3. Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Methodist Hospital San Antonio, Texas

4. Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, Texas

Abstract

Objective Placenta accreta spectrum (PAS) disorders are characterized by an abnormal adherence of the placenta to the uterine myometrium. Magnetic resonance imaging (MRI) is an important adjunct in antenatal diagnosis. We sought to determine if there are patient and MRI characteristics that limit the accuracy of PAS diagnosis and degree of invasion. Study Design We conducted a retrospective cohort analysis of patients who were evaluated for PAS by MRI from January 2007 to December 2020. Patient characteristics evaluated included number of prior cesarean deliveries, history of dilation and curettage (D&C) or dilation and evacuation (D&E), short interval pregnancy less than 18 months, and delivery body mass index (BMI). All patients were followed until delivery and MRI diagnosis was compared with final histopathology. Results Of the 353 patients with suspected PAS, 152 (43%) underwent MRI evaluation and were included in the final analysis. In patients who underwent MRI evaluation, 105 (69%) had confirmed PAS on pathology. Patient characteristics were similar between groups and not associated with accuracy of MRI diagnosis. MRI was accurate in diagnosing PAS and the associated degree of invasion in 83 (55%) patients. Accuracy was associated with lacunae (8 vs. 0%, p = 0.02), abnormal bladder interface (25 vs. 6%, p = 0.002), and T1 hyperintensity (13 vs. 1%, p = 0.002). Of the 69 (45%) patients in whom MRI was inaccurate, overdiagnosis was seen in 44 (64%) patients and underdiagnosis in 25 (36%) patients. Overdiagnosis was significantly associated with dark T2 bands (45 vs. 22%, p = 0.005). Underdiagnosis was associated with earlier gestational age at MRI (28 vs. 30 weeks, p = 0.049) and lateral placentation (16 vs. 2.4%, p = 0.025). Conclusion Patient factors did not change MRI accuracy of PAS diagnosis. MRI is associated with a significant overdiagnosis of PAS when dark T2 bands are present, and underdiagnose PAS when performed earlier in gestation or when lateral placentation is present. Key Points

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology,Pediatrics, Perinatology and Child Health

Reference29 articles.

1. Placenta accreta spectrum;R M Silver;N Engl J Med,2018

2. Placental implantation disorders;E Jauniaux;Obstet Gynecol Clin North Am,2020

3. Placenta accreta spectrum. Obstetric care consensus;ACOG;Obstet Gynecol,2018

4. Center of excellence for placenta accreta;R M Silver;Am J Obstet Gynecol,2015

5. Levels of maternal care. Obstetric care consensus;ACOG;Obstet Gynecol,2019

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3