Femoral Fixation Strength as a Function of Bone Plug Length in Anterior Cruciate Ligament Reconstruction Utilizing Interference Screws

Author:

Light Jonathan J.1ORCID,Firoved Amanda B.2,Rocchi Vanna J.13,Wellman Laurie L.1,Bonner Kevin F.12ORCID

Affiliation:

1. Eastern Virginia Medical School, School of Medicine, Norfolk, Virginia

2. Jordan Young Institute, Orthopaedic Surgery, Sports Medicine, Virginia Beach, Virginia

3. Naval Medicine Center Portsmouth, Orthopaedics, Portsmouth, Virginia

Abstract

Abstract Purpose To determine femoral construct fixation strength as bone plug length decreases in anterior cruciate ligament reconstruction (ACLR). Methods Sixty fresh-frozen bone–patellar tendon–bone allografts were utilized and divided into 20-, 15-, and 10-mm length bone plug groups, subdivided further so that half utilized the patella side (P) for testing and half used the tibial side (T). Ten mm diameter recipient tunnels were created within the anatomic anterior cruciate ligament footprint of 60 cadaveric femurs. All bone plugs were 10 mm in diameter; grafts were fixed using a 7 × 23 mm metal interference screw. An Instron was used to determine the load to failure of each group. A one-way multivariate analysis of variance (MANOVA) was conducted to test the hypothesis that there would be one or more mean differences in fixation stability between 20- or 15-mm plug lengths (P or T) versus 10 mm T plug lengths when cross-compared, with no association between other P or T subgroups. Results The mean load to failure of the 20 mm plugs (20 P + T) was 457 ± 66N, 15 mm plugs (15 P + T) was 437 ± 74N, and 10 mm plugs (10 P + T) was 407 ± 107N. There was no significant difference between P + T groups: 20-versus 15-mm (p = 1.000), 15-versus 10-mm (p = 0.798), and 20-versus 10-mm (p = 0.200); P + T MANOVA (p = 0.291). Within groups, there was no significant difference between patella and tibial bone plug subgroups with a pullout force range between 469 ± 56N and 374 ± 116N and p-value ranging from p = 1.000 for longer bone plugs to p = 0.194 for shorter bone plugs; P versus T MANOVA (p = 0.113). Conclusion In this human time zero cadaver model, there was no significant difference in construct failure between 20-,15-, and 10-mm bone plugs when fixed with an interference screw within the femoral tunnel, although fixation strength did trend down when from 20- to 15- to 10-mm bone plugs. Clinical Relevance There is a balance between optimal bone plug length on the femoral side for achieving adequate fixation as well as minimizing donor site morbidity and facilitating graft passage in ACLR. This study reveals utilizing shorter plugs with interference screw fixation is potentially acceptable on the femoral side if shorter plugs are harvested.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3