Clinical utility of a functional lumen imaging probe in management of dysphagia following head and neck cancer therapies

Author:

Wu Peter12,Szczesniak Michal12,Maclean Julia3,Choo Lennart1,Quon Harry45,Graham Peter6,Zhang Teng12,Cook Ian12

Affiliation:

1. Department of Gastroenterology and Hepatology, St George Hospital, Sydney, New South Wales, Australia

2. St George Clinical School, University of New South Wales, Sydney, New South Wales, Australia

3. Speech Pathology Department, St George Hospital, Sydney, New South Wales, Australia

4. Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Hospital, Baltimore, Maryland, USA

5. Department of Otolaryngology – Head and Neck Surgery, Johns Hopkins University, Baltimore, Maryland, USA

6. Department of Radiation Oncology, Cancer Care Centre, St George Hospital, Sydney, New South Wales, Australia

Abstract

Abstract Background and aims Chemoradiotherapy for head and neck cancer (HNC) with/without laryngectomy commonly causes dysphagia. Pharyngoesophageal junction (PEJ) stricturing is an important contributor. We aimed to validate a functional lumen imaging probe (the EndoFLIP system) as a tool for quantitating pretreatment PEJ distensibility and treatment-related changes in HNC survivors with dysphagia and to evaluate the diagnostic accuracy of EndoFLIP-derived distensibility in detecting PEJ strictures. Methods We studied 34 consecutive HNC survivors with long-term (> 12 months) dysphagia who underwent endoscopic dilation for suspected strictures. Twenty non-dysphagic patients undergoing routine endoscopy served as controls. PEJ distensibility was measured at endoscopy with the EndoFLIP system pre- and post-dilation. PEJ stricture was defined as the presence of a mucosal tear post-dilation. Results PEJ stricture was confirmed in 22/34 HNC patients (65 %). During distension up to 60 mmHg, the mean EndoFLIP-derived narrowest cross-sectional area (nCSA) in HNC patients with strictures, without strictures, and in controls were 58 mm2 (95 % confidence interval [CI] 22 to 118), 195 mm2 (95 %CI 129 to 334), and 227 mm2 (95 %CI 168 to 316), respectively. A cutoff of 114 mm2 for the nCSA at the PEJ had perfect diagnostic accuracy in detecting strictures (area under the receiver operating characteristic curve = 1). In patients with strictures, a single session of dilation increased the nCSA by 29 mm2 (95 %CI 20 to 37; P < 0.001). In patients with no strictures, dilation caused no change in the nCSA (mean difference 13 mm2 [95 %CI −4 to 30]; P = 0.13). Conclusions EndoFLIP is a highly accurate technique for the detection of PEJ strictures. EndoFLIP may complement conventional diagnostic tools in the detection of pharyngeal outflow obstruction.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3