Decreasing Patient Radiation Exposure from Computed Tomography for Hip Preservation Surgery

Author:

Marland Jennifer D.1,Smythe Jason1,Barlow Daniel2,Whiting Daniel3,Payne Brayden4,West Hugh S.1,Wylie James D.1ORCID

Affiliation:

1. The Orthopedic Specialty Hospital, Intermountain Healthcare, Murray, Utah

2. Mercy Family Health Center, Redding, California

3. Northern Rockies Orthopedics, Missoula, Montana

4. Department of Surgery, University Medical Center, Las Vegas, Nevada

Abstract

AbstractThis article describes how we were able to decrease patient radiation exposure from hip computed tomography (CT) for hip preservation evaluation without a degradation of image quality. This is a retrospective review of a quality improvement project. The study included patients who underwent hip CT at a single center as part of a clinical evaluation for young adult hip pain. Four distinct protocols were used during the study period. All protocols included at CT scan of the hip with slices through the distal femur to evaluate femoral version. Patient variables collected included age, gender, and body mass index (BMI). The dose–length product was collected and the effective dose in millisieverts (mSv) was calculated. Differences in dose between protocols were compared using analysis of variance with appropriate post hoc tests and multivariate general linear regression. A total of 613 patients underwent hip CT during the study period with 304 patients in protocol 1, 83 in protocol 2, 136 in protocol 3, and 91 in protocol 4. When controlling for age, gender, and BMI there was a significant decrease in effective dose of radiation from protocol 1 (3.63 mSv) to protocol 2 (3.06 mSv) (p = 0.002) and protocol 2 (3.06 mSv) to protocol 3 (2.16 mSv) (p < 0.001). There was no difference between protocol 3 (2.16 mSv) and protocol 4 (2.10 mSv) (p = 0.269) but protocol 4 was easier to administer. In regression modeling, BMI (p < 0.001) and protocol used (p < 0.001) were independent predictors of effective radiation dose (model R 2 = 0.585). Through a longitudinal clinical quality improvement project, we were able to decrease the effective radiation exposure to patients undergoing hip CT for hip preservation evaluation by close to 50%. Only CT protocol used and patient's BMI were predictors of ionizing radiation exposure. Level of Evidence Level 3, retrospective comparative study.

Publisher

Georg Thieme Verlag KG

Subject

General Earth and Planetary Sciences,General Environmental Science

Reference23 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3