The Suitability of Trabecular Patterns in the Assessment of Dental Implant Osseointegration Process through 2D Digital and 3D CBCT Radiographs

Author:

Putri Annisa1ORCID,Pramanik Farina1,Azhari Azhari1

Affiliation:

1. Department of Dentomaxillofacial Radiology Residency Program, Faculty of Dentistry, Padjadjaran University, Bandung, West Java, Indonesia

Abstract

Abstract Objective The research aims to determine the suitability of the trabecular pattern in the assessment of the dental implant osseointegration process through two-dimensional (2D) digital and three-dimensional (3D) cone-beam computed tomography (CBCT) radiographs. Materials and Methods This is a correlation description that explains the relationship between variables. The population consisted of 24 data points on 3D CBCT and 2D digital radiographs from the procedure after dental implants were inserted into the tibia of a New Zealand white rabbit (Oryctolagus cuniculus) on days 3, 14, and 28. The radiograph was selected based on the region of interest (ROI), which covers the peri-implant area with a width of 1 mm and length following the height of the implant. The ROI was analyzed for trabecular thickness (Tb.Th), separation (Tb.Sp), number (Tb.N), and fractal dimension. Statistical Analysis The intraclass correlation coefficient (ICC) was used to statistically test the data to assess the consistency of intraobserver measurements and the r value (Pearson's correlation coefficient). This determines the correlation between trabecular patterns in both radiographic modalities and the Bland–Altman plot to observe the limits of acceptable discrepancies. Results The ICC test showed high intraobserver consistency in trabecular pattern measurements on 2D digital radiographs and 3D CBCT. The trabecular space pattern and number showed an r value of 0.88 with radiographic modalities of 0.72 mm and 0.018, respectively. Additionally, the trabecular thickness and fractal dimension had an insignificant correlation, with an r value of 0.22, and the mean of the 2D radiograph was lower than that of CBCT. Conclusion The 2D radiograph and 3D CBCT showed correlations in the trabecular number and space results but had no correlation in the trabecular thickness and fractal dimension results. Based on intraclass correlation analysis, 3D CBCT appeared to be more reliable for measuring trabecular patterns (Tb.Th, Tb.Sp, Tb.N, and fractal dimension) than 2D radiograph.

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry

Reference47 articles.

1. Osseointegration: promise and platitudes;G A Zarb;Int J Prosthodont,2012

2. Primary stability: the password of implant integration;A Gill;J Dent Implant,2012

3. Is primary stability a predictable parameter for loading implant?;R Patil;J. Int. Clin. Dent. Res. Organ.,2016

4. Changes in the fractal dimension, feret diameter, and lacunarity of mandibular alveolar bone during initial healing of dental implants;E Önem;Int J Oral Maxillofac Implants,2012

5. Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard;LdosS Corpas;Clin Oral Implants Res,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3