Can Screening and Confirmatory Testing in the Management of Patients with Primary Aldosteronism be Improved?

Author:

Stowasser Michael1,Ahmed Ashraf1,Guo Zeng1,Wolley Martin1,Ungerer Jacobus2,McWhinney Brett2,Poglitsch Marko3,Gordon Richard1

Affiliation:

1. Endocrine Hypertension Research Centre, University of Queensland Diamantina Institute, Greenslopes and Princess Alexandra Hospitals, Brisbane, Australia

2. Analytical Chemistry Unit, Pathology Queensland, Royal Brisbane and Women’s Hospital, Brisbane, Australia

3. Attoquant Diagnostics, Vienna, Austria

Abstract

AbstractWidespread application of the plasma aldosterone/renin ratio (ARR) as a screening test has led to the recognition that primary aldosteronism (PA) is the most common specifically treatable and potentially curable form of hypertension, accounting for 5–10% of patients. Maximal detection requires accurate diagnostic approaches and awareness and control of factors that confound results, including most antihypertensives, posture, time of day, dietary salt, and plasma potassium. Recent studies have revealed potential for false positives in patients on beta-adrenoceptor blockers, and, when direct renin concentration (but not plasma renin activity) is used to measure renin, in women during the luteal phase of the menstrual cycle or receiving estrogen-containing contraceptives or hormonal replacement therapy. In addition to verapamil slow release, hydralazine and prazosin, moxonidine has minimal effects on the ARR and can be used to control hypertension during work-up. Fludrocortisone suppression testing, while probably the most reliable means of definitively confirming or excluding PA, is time consuming and expensive, requiring a five day inpatient stay. A novel approach, upright (seated) saline infusion suppression testing (SST), has shown excellent reliability with much greater sensitivity than conventional recumbent SST in a recent pilot study, and requires only a day visit. Accurate measurement of aldosterone is essential for each step of PA workup: introduction of new, highly reliable high-throughput mass spectrometric methods into clinical practice has represented a major advance. In response to concerns raised about accuracy of renin assays, new mass spectrometric methods for measuring angiotensin II are currently being assessed in the clinical setting.

Publisher

Georg Thieme Verlag KG

Subject

Biochemistry (medical),Clinical Biochemistry,Endocrinology,Biochemistry,General Medicine,Endocrinology, Diabetes and Metabolism

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3