Birmingham Royal Orthopaedic Hospital (BROH) Femoral Offset—An Ancillary Measure of Adult Dysplasia of the Hip

Author:

Iyengar Karthikeyan P.1ORCID,Fitzpatrick John D.2ORCID,Michalos Michail3,McBryde Callum3,Politis Angelos3,Bache Ed3,Wall Peter3,Botchu Rajesh2ORCID

Affiliation:

1. Department of Orthopedics, Southport & Ormskirk NHS Trust, Southport, United Kingdom

2. Department of Musculoskeletal Radiology, Royal Orthopedic Hospital, Birmingham, United Kingdom

3. Department of Young Adult Hip, Royal Orthopedic Hospital, Birmingham, United Kingdom

Abstract

Abstract Introduction Adult dysplasia of the hip (ADH) is a disorder of abnormal development of the hip joint resulting in a shallow acetabulum and uncovering of the femoral head. Several radiological measurements such as the Tönnis angle (acetabular index), lateral center edge angle of Wiberg, and cross-sectional imaging parameters exist to calculate hip dysplasia. Aims The aim of this article was to describe a new ancillary linear measure of ADH on cross-sectional imaging, the Birmingham Royal Orthopaedic Hospital (BROH) Femoral offset. Patients and Methods Anteroposterior radiographs of the pelvis and computed tomography imaging of 100 consecutive patients with suspected hip dysplasia were reviewed. Demographic details and clinical indications were recorded. Tönnis angle was utilized to measure hip slope on radiographs and the BROH femoral offset was calculated for each patient. Student's t-test and one-way analysis of variance (ANOVA) were performed. Intraclass correlation coefficient analysis was evaluated to assess the reliability between observers. Results There was a total of 100 patients (128 hips) included in the study (60 with normal Tönnis angle, 53 had dysplasia, and 15 had decreased Tönnis angle). The average BROH femoral offset in the dysplastic cohort was increased in comparison to the normal cohort with a statistically significant p-Value of 0.0001. The p-value was 0.00031 on ANOVA. The BROH femoral offset calculation revealed good intra- and interobserver reliability of 0.9 and 0.9, respectively. Conclusion The BROH femoral offset can be an additional index for measuring ADH that is easier to calculate, and reproducible with good intra- and inter-observer reliability on cross-sectional imaging.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3