Comparison of Contrast-Enhanced 3D Imaging with 2D Imaging in the Evaluation of Perianal Fistula at 3T: A Prospective Observational Study

Author:

KV Abdulla1,Arunachalam Venkatesh Kasi1ORCID,Sherene Haleema1ORCID,Ethiraju Vijayakumaran1,Ranganathan Rupa1ORCID,SM Gowtham1,Rajasekaran Sriman1,Mehta Pankaj1,Cherian Mathew1

Affiliation:

1. Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India

Abstract

Abstract Introduction Perianal fistula and its recurrence is a challenging entity for surgeons. It is a well-establi1shed fact that magnetic resonance imaging (MRI) findings influence surgical procedures and reduce the rate of recurrence. In this study, we assessed the contrast-enhanced (CE) three dimensional T1 sequences [sampling perfection with application optimized contrast using different flip angle evolution (SPACE) and volumetric interpolated breath-hold examination (VIBE)] in a 3T MRI system to evaluate perianal fistulas and compared them with two-dimensional (2D) sequences. Materials and Methods Forty-four patients (mean age, 38.8 ± 15.3 [standard deviation]; 32 males, 12 females) with perianal fistula were included in this prospective study. The patients underwent conventional noncontrast, 2D sequences, diffusion-weighted imaging, followed by postcontrast, 2D T1 images in both axial and coronal planes, and 3D sequences at 3T. Acquisition times were recorded for each sequence. Each postcontrast sequence was evaluated in terms of image quality, presence of artifacts, fistula type, presence of an abscess, visibility, and number of internal orifices. The surgical findings were considered the gold standard. The imaging findings were compared with the surgical findings. Results In all three sequences, the fistula type and abscess were identified correctly in all patients. The sensitivity value for identification of ramifications utilizing CE 3D T1 VIBE sequence, CE 3D T1 SPACE, and CE 2D T1 images was 100, 86, and 36%, respectively. The number of internal orifices was identified by the CE 3D T1 VIBE and CE 3D T1 SPACE sequences in 100 and 92% of patients, respectively. CE 2D T1 images correctly identified internal orifices in 80% of patients. The overall scan time for each 3D sequence was shorter than for the combined postcontrast 2D sequences. Conclusion CE 3D T1 SPACE and CE 3D T1 VIBE sequences outperformed conventional CE 2D sequences in the evaluation of perianal fistulas in terms of visibility and the number of internal orifices with a shorter scanning time. Among the 3D sequences, CE 3D T1 VIBE is slightly superior to CE 3D T1 SPACE sequence.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Reference19 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3