The use of noninvasive measurements of intracranial pressure in patients with traumatic brain injury: a narrative review

Author:

Faria Bárbara Caroline Dias1ORCID,Sacramento Luiz Gustavo Guimarães1ORCID,Queiroz André Vitor Rocha1ORCID,Leite Fernanda de Andrade Dias2ORCID,Oliveira Henrique Lacerda Lage Lopes de1ORCID,Kimura Thais Yuki1ORCID,Faleiro Rodrigo Moreira123ORCID

Affiliation:

1. Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil.

2. Faculdade de Ciências Médicas de Minas Gerais, Belo Horizonte MG, Brazil.

3. Hospital João XXIII, Belo Horizonte MG, Brazil.

Abstract

Abstract Background The most frequent cause of death in neurosurgical patients is due to the increase in intracranial pressure (ICP); consequently, adequate monitoring of this parameter is extremely important. Objectives In this study, we aimed to analyze the accuracy of noninvasive measurement methods for intracranial hypertension (IH) in patients with traumatic brain injury (TBI). Methods The data were obtained from the PubMed database, using the following terms: intracranial pressure, noninvasive, monitoring, assessment, and measurement. The selected articles date from 1980 to 2021, all of which were observational studies or clinical trials, in English and specifying ICP measurement in TBI. At the end of the selection, 21 articles were included in this review. Results The optic nerve sheath diameter (ONSD), pupillometry, transcranial doppler (TCD), multimodal combination, brain compliance using ICP waveform (ICPW), HeadSense, and Visual flash evoked pressure (FVEP) were analyzed. Pupillometry was not found to correlate with ICP, while HeadSense monitor and the FVEP method appear to have good correlation, but sensitivity and specificity data are not available. The ONSD and TCD methods showed good-to-moderate accuracy on invasive ICP values and potential to detect IH in most studies. Furthermore, multimodal combination may reduce the error possibility related to each technique. Finally, ICPW showed good accuracy to ICP values, but this analysis included TBI and non-TBI patients in the same sample. Conclusions Noninvasive ICP monitoring methods may be used in the near future to guide TBI patients' management.

Publisher

Georg Thieme Verlag KG

Subject

Neurology,Neurology (clinical)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3