Minimally Invasive Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Three 5.5-mm Cortical Screws Inserted in Lag Fashion and Two 7.0-mm Headless Cannulated Dual-Pitch Compression Screws

Author:

Rumpel Aires Santana1ORCID,De Carvalho Anderson Luiz1,Vassoler Jakson Manfredini2ORCID,Schmidt Matheus Lothar3,Mertz Cleiton Costa3,Rozo Cesar Augusto Camacho1,Campos Joanna Kulczynski1,Alievi Marcelo Meller1ORCID

Affiliation:

1. Department of Animal Medicine, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil

2. Department of Mechanical Engineering, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil

3. Post-Graduation Program in Mining, Metallurgical and Materials Engineering, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil

Abstract

Abstract Objective The aim of this study was to compare the biomechanical properties of two minimally invasive arthrodesis techniques of the equine proximal interphalangeal (PIP) joint (three transarticular 5.5-mm cortical screws [AO-3TLS] vs. two transarticular 7.0-mm headless cannulated multi-use compression screws [MUC-2TS]) in dynamic non-destructive testing and compression testing to failure. Study Design The experimental study included six pairs of cadaveric adult equine forelimbs; one limb from each horse was randomly assigned to one of the treatments, and the contralateral limb was submitted to the remaining treatment. The dynamic test was performed alternating non-destructive compression tests at a displacement rate of 5 mm/min up to 5,000 N and sinusoidal compressive cyclic tests at 6 Hz, using a 3,600-N amplitude for 8,550 cycles. Construct stiffness and maximum sagittal plane rotation about the PIP joint markers were determined during the dynamic test. After the dynamic test reached 136,800 cycles, the monotonic compressive test until failure was performed on each construct: load, displacement and sagittal plane rotation about the PIP joint marker at failure were analysed. Results The evaluated biomechanical properties showed no statistical difference between the AO-3TLS and MUC-2TS treatment groups in any of the ramps of the dynamic non-destructive test and in the compression loading until failure test. Conclusion The MUC-2TS treatment produced biomechanical properties equivalent to the AO-3TLS treatment for PIP joint arthrodesis.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

Reference29 articles.

1. A limited surgical approach for pastern arthrodesis in horses with severe osteoarthritis;P Jones;Vet Comp Orthop Traumatol,2009

2. Arthrodesis techniques in horses;C J Zubrod;Vet Clin North Am Equine Pract,2005

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3