Complications of Different Types of Cranioplasty and Identification of Risk Factors Associated with Cranioplasty at a Tertiary Care Centre: A Prospective Observational Study

Author:

Shukla Yatendra1,Sundaram Ponraj Kamatchi1ORCID,Ramalingam Jinendra Kumar1ORCID,Costa Jorson D1,Parab Amey1,Jakhar Subhash1,Chauhan Ganesh2ORCID,Bharti Rohit1ORCID

Affiliation:

1. Department of Neurosurgery, Goa Medical College, Goa, India

2. Rajendra Institute of Medical Sciences, Ranchi, India

Abstract

Abstract Objective Decompressive craniectomy (DC) is an urgent procedure which is done to decrease intracranial pressure. A study of the complications would suggest measures to improve the care. This study was focused on analyzing the complications after cranioplasty (CP) and to identify risk factors that may be associated with the failure of the procedure. Method: This study was conducted over 41 months at level-1 trauma center and medical college. It included patients undergoing CP for a defect arising out of previous DC or inability to replace the bone flap (Glasgow Coma Scale > 13, size > 5 cm, without surgical site infection). All patients underwent CT imaging before and after the procedure. The CP technique largely depended on the patients, based on the cost of prosthesis and availability. Result: Hundred patients were included in the study. Postoperatively, total 22 patients suffered complications of which few had more than one complication. Titanium implant appeared to be a better implant, with no complication (p < 0.05). Complication was common in younger age group, chemically cured PMMA (polymethyl methacrylate) and ethylene oxide) sterilized bone flap). Complications were higher among patients with multiple comorbidity and stroke patients. Conclusion: Titanium flap had no complication and in case of autologous abdominal subcutaneous flap, apart from bone flap absorption, patients had no major complication. Therefore, both implants are preferred implants for CP. Heat-cured PMMA can be used in case of nonavailability of a better option, as it is economical feasible and can be molded at any dental lab.

Publisher

Georg Thieme Verlag KG

Subject

Materials Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3