Suture-Based Distal Radioulnar Joint Stabilization: A Biomechanical Evaluation in a Cadaveric Model

Author:

Graf Alexander R.1ORCID,Ahmed Adil S.2,Thompson Dan2,Gottschalk Michael B.2,Wagner Eric R.2,Suh Nina2

Affiliation:

1. Division of Hand and Upper Extremity, Department of Orthopedic Surgery, Medical College of Wisconsin, Milwaukee, Wisconsin

2. Division of Hand and Upper Extremity, Department of Orthopedic Surgery, Emory University, Atlanta, Georgia

Abstract

Abstract Purpose Management of acute distal radioulnar joint (DRUJ) instability is complex and controversial. Common treatment options include prolonged immobilization, stabilization with wires, and acute triangular fibrocartilage complex repair. However, none of these permits an early range of motion. The purpose of this study is to investigate the feasibility of a suture-based stabilization (SBS) technique for acute DRUJ instability to permit early active motion. Methods A biomechanical study utilizing eight cadaveric arms was performed. All specimens were tested in the intact state prior to the creation of bidirectional DRUJ instability. For the SBS group, 2-mm suture tapes with suture button fixation were utilized to recreate the respective contributions of distal oblique bundle and volar and dorsal radioulnar ligaments to DRUJ stability. All specimens were cyclically loaded with a simulated ballottement stress of 20N in forearm positions of neutral, 60 degrees of pronation and 60 degrees of supination. Range of motion and total translation were measured and then compared between the two groups. Results The average range of motion in the intact and SBS specimens was 174 and 175 degrees, respectively. There were no significant differences in displacement between the intact and SBS group in neutral and in supination. However, the SBS group had less translation than the intact group in pronation. Conclusions For acute DRUJ instability, the described SBS technique provides similar stability to the native intact DRUJ without compromising the range of motion in a cadaveric model. Future comparative studies are warranted prior to translation into the clinical arena. Clinical Relevance This is a biomechanical study investigating a treatment technique for acute DRUJ instability that would allow an early range of motion.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3