Interosseus Membrane Reconstruction Following a Forearm Injury: A Case Report

Author:

Shine S.J.1ORCID,Bamberger H.B.2,Spieser C.E.3,Sferrella A.M.4

Affiliation:

1. Fourth Year Orthopedic Surgery Resident, Department of Orthopedic Surgery, Kettering Health Network, Grandview Medical Center, Dayton, Ohio

2. Orthopedic Hand and Upper Extremity Specialist, Department of Orthopedic Surgery, Kettering Health Network, Grandview Medical Center, Dayton, Ohio

3. Fourth Year Medical Student, Ohio University Heritage College of Osteopathic Medicine, Athens, Ohio

4. Fourth Year Medical Student, College of Osteopathic Medicine, Marian University, Indianapolis, Indiana

Abstract

Abstract Background Essex-Lopresti injuries are complex, frequently missed forearm/elbow injuries consisting of a fracture of the radial head with disruption of both the distal radioulnar joint (DRUJ) and the interosseous membrane (IOM). Ideal management of these injuries remains controversial, especially in relation to the IOM, due in part to underdiagnosis of IOM injury and incomplete understanding of the IOM role. Methods A 43-year-old man sustained an open radial shaft fracture with associated radial head subluxation, coronoid base fracture, and DRUJ injury with ulnar head subluxation. He was taken for surgery, where elbow instability with near complete disruption of the IOM was observed. Persistent gross rotational instability was noted following radius fixation, so braided suture and button reconstruction of the central band of the IOM was performed. This restored rotational and longitudinal stability to the radiocapitellar joint and DRUJ. Over 1 year out from the index surgery, the patient's elbow and DRUJ have remained stable, and he is back working as a laborer. Results While little literature exists on outcomes of acute IOM reconstruction in these injuries, recent biomechanical studies have shown the importance of the central band on rotational elbow stability. Conclusion This case supports the importance of the central band of the IOM by demonstrating the impact of its repair on the longitudinal and rotational stability of the elbow and DRUJ. IOM repair has the potential to improve our treatment of this complicated injury by better restoring forearm stability and function of the elbow, which future studies could help further elucidate.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3