Determining the Best Thyroid Imaging Reporting and Data System: A Prospective Study Comparing the Diagnostic Performance of ACR, EU, and K TIRADS in the Evaluation of Thyroid Nodules

Author:

Mohan Supraja Laguduva1,Govindarajalou Ramkumar1ORCID,Naik Dukhabandhu2,Saxena Sunil Kumar3,Toi Pampa Ch.4,V. Gomathi Shankar5

Affiliation:

1. Department of Radiodiagnosis, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

2. Department of Endocrinology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

3. Department of Otorhinolaryngology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

4. Department of Pathology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

5. Department of Surgery, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

Abstract

Abstract Background Many different risk stratification systems have been formulated for thyroid nodules, differing in their fine-needle aspiration cytology (FNAC) indication, suggesting a lack of consensus around the world. Purpose This prospective study was conducted to find the best guideline for risk stratification, for a better malignancy yield, and with reduced rates of negative FNACs among three Thyroid Imaging, Reporting, and Data System (TIRADS) guidelines. Materials and Methods A total of 625 thyroid nodules with conclusive FNAC or histopathological diagnosis were included in the study. Various sonographic parameters were recorded. They were classified into categories as per the three guidelines and compared with FNAC diagnosis. The guidelines were evaluated in terms of sensitivity, specificity, predictive values, and diagnostic accuracy. Sensitivity and specificity were compared by McNemar's test. Results American College of Radiology (ACR) TIRADS had the highest diagnostic accuracy (56.8%), specificity (50.75%), positive predictive value (23.92%), lowest rates of negative FNACs (76.08%), and high negative predictive value (97.84 %). Korean (K) TIRADS had the maximum sensitivity (97.75%), highest negative predictive value (98.44%), and gross malignancy yield. European TIRADS was between the two other guidelines in most parameters with specificity like K TIRADS. Conclusion All the three guidelines are very good screening tools, with comparable high sensitivity. ACR TIRADS is better in terms of specificity and reduced rates of negative FNACs. Including the presence of a suspicious cervical lymph node as a criterion and more frequent follow-up might further improve the diagnostic performance of the guideline.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3