Safety and efficacy of coaxial lumen-apposing metal stents in the management of refractory gastrointestinal luminal strictures: a multicenter study

Author:

Bazerbachi Fateh1,Heffley Jason2,Abu Dayyeh Barham1,Nieto Jose3,Vargas Eric1,Sawas Tarek1,Zaghlol Raja1,Buttar Navtej1,Topazian Mark1,Wong Kee Song Louis1,Levy Michael1,Keilin Steve2,Cai Qiang2,Willingham Field2

Affiliation:

1. Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, United States

2. Division of Digestive Diseases, Department of Medicine, Emory University, Atlanta, Georgia, United States

3. Borland-Groover Clinic, Jacksonville, Florida, United States

Abstract

Abstract Background and aims Benign gastrointestinal (GI) strictures are often refractory to standard endoscopic interventions. Fully covered coaxial lumen-apposing metal stents (LAMS) have emerged as a novel therapy for these strictures. The aim of this study was to evaluate the safety and efficacy of LAMS for refractory GI strictures. Patients and methods A retrospective analysis was performed for patients who underwent LAMS placement for benign luminal strictures in three US centers between January 2014 and December 2016. The primary outcomes were technical success and initial clinical success of LAMS placement. Secondary outcomes were stent migration, rate of re-intervention, and adverse events. Results A total of 49 patients underwent 56 LAMS placement procedures. Previous treatment had failed in 39 patients (79.6 %), and anastomotic strictures were the indication in 77.6 % (38/49), with the most common site being gastrojejunal (34.7 % [17/49]). Technical success was achieved in all procedures and initial clinical success was achieved in 96.4 % of all procedures (54/56). Patient initial clinical success was 95.9 % (47/49). Stent migration occurred in 17.9 % of procedures, and was more likely to occur at sites in the lower GI tract (P = 0.02). The mean stent dwell time was 100.6 days, and the mean follow-up was 169.8 days. Minor adverse events, not requiring hospitalization, occurred in 33.9 % of procedures, including subsequent stricture progression (10.7 %). In cases where LAMS were removed, mean follow-up time was 102.2 days. The re-intervention rate was 75 % at 300 days follow-up after stent removal. Of the LAMS placed at anastomotic strictures, 36.4 % required re-intervention, with approximately two-thirds of these re-interventions requiring placement of a new stent or surgery. Conclusion LAMS placement was successful for the management of refractory GI strictures, with good technical and initial clinical success rates. However, re-intervention rates after LAMS removal were high, and many strictures were not resolved by an extended period of stenting with these coaxial stents. LAMS placement offers additional therapeutic options and in selected cases might be considered a destination therapy for patients with recalcitrant benign strictures.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3