Abstract

Abstract Introduction This study highlights the relation between compound muscle action potential (CMAP) latency variations and the predictive value of facial nerve (FN) proximal-to-distal (P/D) amplitude ratio measured at the end of vestibular schwannoma resection. Methods Forty-eight patients underwent FN stimulation at the brainstem (proximal) and internal acoustic meatus (distal) using a current intensity of 2 mA. The proximal latency and the P/D amplitude ratio were assessed. House–Brackmann grades I & II indicated good FN function, and grades III to VI were considered fair/poor function. A P/D amplitude ratio > 0.6 was used as a cutoff to indicate a good FN function, while a ratio of ≤ 0.6 indicated a fair/poor FN function. Results The P/D amplitude ratio was measured for all patients, and the calculated sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV) were 85.2, 85.7, 88.5, and 81.8%, respectively. The CMAPs from the mentalis muscle were then classified based on their proximal latency into group I (< 6 ms), group II (6–8 ms), and group III (> 8 ms). The SE, SP, PPV, and NPV became 90.5, 90.9, 95, and 83.3%, respectively, in group II. In group I, SE and NPV increased, whereas SP and PPV decreased. While in group III, SP and PPV increased, whereas SE and NPV decreased. Conclusion At a latency between 6 and 8 ms, the P/D amplitude ratio was predictive of outcomes with high SE and SP. When latency was < 6 ms or > 8 ms, the same predictive ability was not observed. Knowing the strengths and limitations is important for understanding the predictive value of the P/D amplitude ratio.

Publisher

Georg Thieme Verlag KG

Subject

Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3