The Effect of Working Length, Fracture, and Screw Configuration on Plate Strain in a 3.5-mm LCP Bone Model of Comminuted Fractures

Author:

Wainberg S.H.1,Moens N.M.M.1,Ouyang Z.1,Runciman J.2

Affiliation:

1. Department of Clinical Studies, Ontario Veterinary College, Guelph, Ontario, Canada

2. School of Engineering, University of Guelph, Guelph, Ontario, Canada

Abstract

Abstract Introduction This study provides a comprehensive examination of plate strain under realistic fracture configurations. The effect of plate working length, plate contact, fracture length, and position on strain was evaluated using bone surrogates subjected to “load-controlled,” nondestructive conditions. Materials and Methods Five 3.5-mm locking compression plates (LCP) were instrumented with six strain gauges. The gauges were glued between holes in predetermined locations marked by laser engraving. Nine fracture models were created using bone surrogate, each representing a combination of the criteria under study: long versus short working length, degree of plate compression, fracture location, and fracture length. All five plates were tested under each of the nine configurations. The constructs were mounted in an Instron testing machine with a 5-kN load cell. Each specimen was cyclically loaded at a rate of 5 mm/min to 50, 100, and 200 N. Results Decreased plate strain was noted with a short plate working length in all fracture configurations (p < 0.05). Increasing the plate working length increased the strain at higher loads and on the plate adjacent to the fracture gap. The size of the fracture gap and fracture location had minimal effects on plate strain (p < 0.05). Elevation of the plate off the bone (1.5 mm) resulted in increased plate strain under all loading conditions (p < 0.05). Conclusion Our null hypothesis was rejected in that a short plate working length resulted in decreased plate strain in all comminuted fracture configurations. Our secondary hypothesis was validated in that elevation of the plate from the bone resulted in increased strain in all configurations. As plate strain identifies regions of mechanical weakness whereby a construct may prematurely fail by acute overload or cyclic fatigue, identifying factors that may increase plate strain allows the surgeon to reduce these variables as much as possible to reduce the incidence of implant failure and subsequent fracture failure.

Publisher

Georg Thieme Verlag KG

Subject

General Agricultural and Biological Sciences

Reference22 articles.

1. Biomechanical concepts applicable to minimally invasive fracture repair in small animals;P Chao;Vet Clin North Am Small Anim Pract,2012

2. The use and abuse of locking plates;P Szypryt;Orthop Trauma,2009

3. The concept of locking plates;P Cronier;Orthop Traumatol Surg Res,2010

4. Locking plates: tips and tricks;W R Smith;J Bone Joint Surg Am,2007

5. Indications and limitations of locked plating;S LE Tan;Injury,2009