Dimensional Optimization of Graphene-Modified Polymethyl Methacrylate Material Used as an Aesthetic Removable Partial Denture Clasp Material

Author:

Hussein Mostafa Omran1ORCID

Affiliation:

1. Department of Prosthodontic Sciences, College of Dentistry in Ar Rass, Qassim University, Saudi Arabia

Abstract

Abstract Objective Although graphene-modified polymethyl methacrylate material is a good candidate for partial denture clasp material, it lacks adequate strength. Therefore, the study aims to assess the optimal dimension of this nanomodified material required for such an application. Materials and Methods A parametric finite element analysis study was conducted on 54 clasp 3D models at two displacement levels (0.25–0.5 mm) placed 3 mm from the clasp tip. The clasp models were categorized based on the dimensions into A, B, and C (3 subgroups in each) and six tapers from the tip to the base (0.5–1). Both reaction force in (N) and maximum principal stress in (MPa) were recorded and analyzed. The study was validated using the mechanical tester after digital manufacturing of the clasp specimens that showed satisfactory results. Statistical Analysis The correlations between width and thickness against reaction force and maximum principal stress were checked by a statistical analysis software package (SPSS version 22; IBM Corp., Armonk, New York, United States). Data of the reaction force demonstrated nonparametric behavior, as tested by the Kolmogorov–Smirnov test. Accordingly, Spearman's rho test for correlation was used. In contrast, the maximum principal stress data showed normal distribution, as tested by the Kolmogorov–Smirnov test. Thus, Pearson's test of correlation was applied. Results The results demonstrated the best retention force values, considering aesthetics, in subgroups C3 (taper 0.6), C3 (taper 0.8), and B3 (taper 1). The maximum principal stress results showed the highest values in group C followed by group B and then group A. Positive correlations were calculated between thickness and width versus reaction force and maximum principal stress. The correlation coefficient value between thickness and reaction force was 0.699 and that between width and reaction force was 0.621, while the correlation coefficient between thickness and maximum principal force was 0.899 and that between the width and maximum principal force was 0.740. Conclusion It could be concluded that the studied material might be recommended as a valid aesthetic clasp material. Both clasp thickness and width showed a positive correlation with the clasp retention force with more impact by the thickness.

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3