Abstract

Abstract Background and study aims Sessile serrated adenomas (SSA) and traditional serrated adenomas (TSA) have been increasingly recognized as precursors of colorectal cancer. The aim of this study was to compare the effect of carbon dioxide insufflation (CO2I) vs. room air insufflation (AI) on serrated polyp detection rate (SPDR) and to identify factors associated with SPDR. Patients and methods Single-center retrospective cohort study of 2083 screening colonoscopies performed with AI (November 2011 through January 2013) or CO2I (February 2013 to June 2015). Data on demographics, procedure characteristics and histology results were obtained from a prospectively maintained endoscopy database and chart review. SPDR was defined as proportion of colonoscopies in which ≥ 1 SSA, TSA or hyperplastic polyp (HP) ≥ 10 mm in the right colon was detected. Multi-variate analysis (MVA) was performed to identify predictors of SPDR. Results A total of 131 histologically confirmed serrated polyps (129 SSA, 2 TSA and 0 HP ≥ 10 mm) were detected. SPDR was higher with CO2I vs. AI (4.8 % vs. 1.4 %; P < 0.0001). On MVA, CO2I was associated with higher SPDR when compared to AI (OR: 9.52; 95 % CI: 3.05 – 30.3). Both higher body mass index (OR 1.05; 95 % CI:1.02 – 1.09) and longer colonoscope withdrawal time (OR 1.11; 95 % CI: 1.07 – 1.16) were also associated with higher SPDR. Conclusion CO2I is associated with higher SPDR when compared to AI during screening colonoscopy. While the mechanism remains unknown, we speculate that the favorable gas characteristics of CO2 compared to room air results in improved polyp detection by optimizing bowel insufflation. These findings suggest an additional reason to prefer the use of CO2I over AI during colonoscopy.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3