A randomized trial comparing winged versus conventional plastic stents for malignant bile duct strictures

Author:

Ayres Lachlan1,Cheriyan Danny12,Scott Ryan3,Kim Edward1,Lee Terry4,Singer Joel4,Donnellan Fergal5,Byrne Michael5,Weiss Alan5,Enns Robert16,Amar Jack1,Lam Eric1,Telford Jennifer1

Affiliation:

1. St. Paul’s Hospital – Gastroenterology, Vancouver, Canada

2. Beaumont Hospital, Dublin – Gastroenterology, Dublin, Ireland

3. Belfast City Hospital – Gastroenterology, Belfast, United Kingdom of Great Britain and Northern Ireland

4. St Paul’s Hospital – Medical Statistics, Vancouver, Canada

5. Vancouver General Hospital – Gastroenterology, Vancouver, Canada

6. University of British Columbia, Division of Gastronterology, Department of Medicine, Vancouver, Canada

Abstract

Abstract Background and study aims Stent insertion at endoscopic retrograde cholangiopancreatography (ERCP) is an established therapy for managing malignant biliary obstruction. Conventional plastic stents with a tubular design are most commonly used despite limited patency. Plastic stents with a winged design may theoretically increase the duration of stent patency. The aim of this study was to compare stent patency of the winged versus conventional plastic stents in patients with malignant biliary obstruction. Patients and methods A prospective, randomized subject-blinded trial was conducted. Patients with malignant biliary obstruction were randomized (1:1) to either a 10 French winged stent or 7 or 10 French conventional plastic stent. Strictures greater than 1 cm distal to the hilum were included. Patients were followed clinically to determine the frequency of stent failure until surgery, death or study closure. Results Fifty-eight patients were enrolled. Following 9 exclusions, 49 patients were randomized to a winged (n = 23) or conventional stent (n = 26). Median time to stent failure was 89 (95 % CI 26-NA) vs 143 (95 % CI 33 – 266) days (P = 0.963) for the winged and conventional group, respectively. Stent failure for the winged group occurred in 11 (48 %) compared to 14 (54 %) in the conventional group. Median survival was 123 (95 % CI 81 – 189) vs 342 days (95 % CI 123 – 704) (p = 0.084) in the winged and conventional group respectively. There were no procedure related adverse events. Conclusions Improvement in stent patency was not seen with the winged stent when compared to the conventional plastic stent. Clinical trials number NCT01514214.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3