Evolution of Hemostasis Testing: A Personal Reflection Covering over 40 Years of History*

Author:

Favaloro Emmanuel J.123ORCID

Affiliation:

1. Department of Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), Sydney Centres for Thrombosis and Haemostasis, NSW Health Pathology, Westmead Hospital, Westmead, NSW Australia

2. School of Dentistry and Medical Sciences, Faculty of Science and Health, Charles Sturt University, Wagga Wagga, New South Wales, Australia

3. School of Medical Sciences, Faculty of Medicine and Health, University of Sydney, Westmead Hospital, Westmead, New South Wales, Australia

Abstract

AbstractThere is no certainty in change, other than change is certain. As Seminars in Thrombosis and Hemostasis celebrates 50 years of publication, I felt it appropriate to reflect on my own 40-year plus scientific career. My career in the thrombosis and hemostasis field did not start until 1987, but the subsequent 35 years reflected a period of significant change in associated disease diagnostics. I started in the Westmead Hospital “coagulation laboratory” when staff were still performing manual clotting tests, using stopwatches, pipettes, test tubes, and a water bath, which we transported to the hospital outpatient department to run our weekly warfarin clinic. Several hemostasis instruments have come and gone, including the Coag-A-Mate X2, the ACL-300R, the MDA-180, the BCS XP, and several StaR Evolution analyzers. Some instruments remain, including the PFA-100, PFA-200, the AggRAM, the CS-5100, an AcuStar, a Hydrasys gel system, and two ACL-TOP 750s. We still have a water bath, but this is primarily used to defrost frozen samples, and manual clotting tests are only used to teach visiting medical students. We have migrated across several methodologies in the 45-year history of the local laboratory. Laurel gel rockets, used for several assays in the 1980s, were replaced with enzyme-linked immunosorbent assay assays and most assays were eventually placed on automated instruments. Radio-isotopic assays, used in the 1980s, were replaced by an alternate safer method or else abandoned. Test numbers have increased markedly over time. The approximately 31,000 hemostasis assays performed at the Westmead-based laboratory in 1983 had become approximately 200,000 in 2022, a sixfold increase. Some 90,000 prothrombin times and activated partial thromboplastic times are now performed at this laboratory per year. Thrombophilia assays were added to the test repertoires over time, as were the tests to measure several anticoagulant drugs, most recently the direct oral anticoagulants. I hope my personal history, reflecting on the changes in hemostasis testing over my career to date in the field, is found to be of interest to the readership, and I hope they forgive any inaccuracies I have introduced in this reflection of the past.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Hematology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3