Influence of Implant Adjacent Teeth on the Accuracy of Digital Impression

Author:

Abduo Jaafar1ORCID,El-Haddad Hossam1ORCID

Affiliation:

1. Department of Prosthodontics, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia

Abstract

Abstract Objective The aim of this study was to evaluate the effect of adjacent teeth patterns on the accuracy of digital scans of parallel and divergent implants for three-unit prostheses. Materials and Methods A maxillary typodont model with implants in the locations of the first premolars and first molars was used to develop three clinical scenarios for three-unit prostheses: (S1) Partially edentulous arch with missing first premolars and first molars only; (S2) partially edentulous arch with missing first premolars, second premolars and first molars; and (S3) partially edentulous arch with missing canines, first premolars, second premolars, first molars, and second molars. On one side, the implants were parallel, and for the other side, the implants had a 15-degree buccolingual angle. With the aid of scan bodies, 10 digital impressions were taken for each scenario and for each side. To evaluate the accuracy, a reverse engineering software was used to measure trueness, precision, and interimplant distance. Results The best trueness for parallel implants was observed for S2 (30.0 µm), followed by S3 (67.3 µm) and S1 (74.8 µm) (p < 0.001). Likewise, S2 had the best precision for parallel implants (31.3 µm) followed by S3 (38.0 µm) and S1 (70.3 µm) (p < 0.001). For the divergent implants, S2 exhibited the best trueness (23.1 µm), followed by S3 (48.2 µm) and S1 (59.4 µm) (p = 0.007). Similarly, the S2 had the best precision (12.3 µm) followed by S3 (62.1 µm) and S1 (66.9 µm) (p < 0.001). The S2 had the least interimplant distance deviation followed by S1 and S3. The difference was significant for parallel implants (p = 0.03), but insignificant for divergent implants (p = 0.15). Conclusion Regardless of the presenting scenario, digital implant impressions for three-unit prostheses appear to be clinically accurate. A clear interimplant area between scan bodies enhanced the accuracy of digital impressions. This observation can be attributed to more accessible axial surface scanning of the scan body.

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3