Accuracy of Conventional Instrumentation is Dependent on Alignment Philosophy Using the Identical Surgical Technique in Total Knee Arthroplasty

Author:

Koutp Amir1,Clar Clemens1,Leitner Lukas1,Fischerauer Stefan1,Reinbacher Patrick1,Leithner Andreas1,Klasan Antonio2ORCID,Sadoghi Patrick1

Affiliation:

1. Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria

2. Department of Orthopaedics and Traumatology, AUVA UKH Steiermark, Graz, Austria

Abstract

AbstractThe objective of this prospective study was to assess the precision of restoring the anatomical tibial obliquity, as measured by the medial proximal tibial angle (MPTA) on conventional X-rays, in relation to the surgical technique employed. Specifically, the study aimed to compare the accuracy of tibial obliquity restoration between kinematic alignment (KA) and conventional mechanical alignment (MA) in total knee arthroplasty (TKA). Two-hundred-and-sixty patients underwent either mechanically aligned TKA (n = 139) or kinematically aligned TKA (n = 121) using conventional instrumentation (CI). Pre- and postoperative X-rays were measured twice by two observers, with a 2-week interval. Inter- and intraclass correlations were calculated, and postoperative tibial obliquity was compared to the preoperative anatomy. In the group of 139 patients with mechanically aligned TKA, no cases with an MPTA deviation greater than 1 degree from 90 degrees were observed. Sixteen percent of the cases (n = 22) had a deviation of 0 to 1 degree. The remaining 84% of the cases (n = 117) had their MPTA of 90 degrees achieved. In the group of 121 patients with kinematically aligned TKA, no cases had a deviation greater than 1 degree compared with the preoperative MPTA. Thirty-one percent of the cases (n = 37) had a deviation of 0 to 1 degree with respect to preoperative MPTA. The remaining 69% of the cases (n = 84) had their tibial obliquity restored. Mechanically aligned TKA revealed statistically significant smaller deviations of accuracy compared to kinematically aligned TKA (p = 0.005). The inter- and intraclass correlations indicated substantial agreement of all measurements (intraclass correlation coefficient [ICC] < 0.90). Both mechanically aligned and kinematically aligned TKA demonstrated satisfactory outcomes in terms of restoring tibial obliquity or a neutral MPTA of 90 degrees using CI. However, MA showed superior results regarding precision compared to KA. When starting with kinematical alignment using CI, the surgeons should be aware that the learning curve according to accuracy differs to MA. It was a Prospective Level II study.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3